Turck
Turck BI10-G30SK-Y1X 40220 Inductive Sensor M30×1.5 10mm 154g
M30×1.5 flush-mount inductive sensor with 10 mm switching distance, NAMUR DC 2-wire output at 8.2 VDC, chrome-plated brass housing and terminal chamber, 154 g
- TypeTest Equipment
- Item Count1 pack
- Selling UnitBox
- Parts3 Years
- Labor1 Year
- 10 mm flush sensing range for reliable metal detection
- M30 × 1.5 threaded barrel fits standard mounting points
- NAMUR output per DIN EN 60947-5-6 for intrinsic safety circuits
- Chrome-plated brass housing resists corrosion in harsh environments
- Terminal chamber simplifies field wiring and maintenance
Inductive Sensor M30 × 1.5
The Turck BI10-G30SK-Y1X 40220 is a flush-mount inductive sensor built for industrial detection tasks. Its threaded brass barrel fits M30 × 1.5 openings and carries a chrome-plated finish for durability. The device operates on a nominal 8.2 VDC supply using a two-wire NAMUR output. It is supplied new in a single-unit box.
Rated Switching Distance 10 mm
The sensor detects metal targets at a rated switching distance of 10 mm. This figure determines whether the unit suits the required sensing range in a given application. Output behaviour follows the DIN EN 60947-5-6 standard for NAMUR interfaces. Connection is made through an integrated terminal chamber.
Low-Power DC Operation
Running on a nominal 8.2 VDC two-wire circuit, the sensor draws minimal current in normal use. The all-metal housing acts as a heat path, so the unit stays cool without active cooling. No moving parts means silent operation in cabinets or on machines. The 154 g weight adds negligible load to mounting brackets.
Highlights
- 10 mm flush sensing range for reliable metal detection
- M30 × 1.5 threaded barrel fits standard mounting points
- NAMUR output per DIN EN 60947-5-6 for intrinsic safety circuits
- Chrome-plated brass housing resists corrosion in harsh environments
- Terminal chamber simplifies field wiring and maintenance
Specifications
| Brand | TURCK |
|---|---|
| Model | BI10-G30SK-Y1X 40220 |
| Type | Test Equipment |
| Item Count | 1 pack |
| Selling Unit | Box |
| Parts | 3 Years |
| Labor | 1 Year |
Questions about this item
What does the 10 mm rated switching distance mean when the sensor is mounted in a machine?
It detects a standard steel target at up to 10 mm when flush-mounted in metal, giving a reliable trigger point for position-sensing tasks.
The output follows DIN EN 60947-5-6 (NAMUR) at a nominal 8.2 VDC — what does that limit in practice?
The two-wire NAMUR interface delivers a current-change signal rather than a voltage level, so it must connect to a NAMUR-compatible input or isolated barrier, not a standard PLC digital input.
The housing is a threaded M30 × 1.5 barrel — what clearance and mounting style does it need?
It requires a 30 mm diameter clearance hole with 1.5 mm pitch threads and installs flush in metal, secured by the chrome-plated brass barrel and lock nuts.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.