Tripp Lite
Tripp Lite SRCOOLDXRW25 In-Row Precision Cooling 25.8 kW 208V 42U 300mm
In-row precision cooling delivers 25.8 kW capacity with 2,950 CFM airflow in a 300 mm, 42U cabinet operating on 208 V three-phase power
- TypeAir Conditioners
- ColorBlack
- SpecificationsINPUT Electrical Consumption (Max): 10 kW Nominal Input Volt
- FeaturesSlim Air Conditioning System Saves Space While Delivering Pr
- 8 kW cooling capacity handles dense server loads
- Inverter compressor and EC fans cut energy use to 10 kW max
- 300 mm wide 42U frame fits standard row layouts
- 2,950 CFM airflow with active DX cooling targets hot spots
- 7-inch colour touchscreen gives instant status and alerts
25.8 kW In-Row Cooling for 42U Racks
The Tripp Lite SRCOOLDXRW25 is a 300 mm wide in-row precision cooling unit built for 42U server cabinets. It delivers 25.8 kW (88,000 BTU) of active DX cooling using R410a refrigerant. The system targets data-centre operators who need primary cooling inside the row without sacrificing rack space. It runs on 208V AC three-phase power at 60 Hz.
Sustained Load Behaviour
Under continuous operation the inverter-driven compressor and EC fans modulate capacity to match the thermal load while drawing a maximum of 10 kW electrical input. Airflow reaches 2,950 CFM and audible noise stays at 68 dBA. The unit is rated for ambient temperatures from 4°F to 115°F (-16°C to 46°C) and humidity from 5% to 80%, with an operating elevation limit of 13,123 ft (4,000 m).
Installation and Common Issues
The cabinet fits standard 42U rows and connects via 3-wire or 4-wire plus ground input; maximum current is 27 A. A 7-inch colour touchscreen on the front panel provides local control and alerts. Installers must allow for condensate drainage and verify that the 17.4 lb (8.0 kg) refrigerant charge complies with local regulations. The unit is not suited for environments exceeding the stated temperature or humidity ranges.
Highlights
- 8 kW cooling capacity handles dense server loads
- Inverter compressor and EC fans cut energy use to 10 kW max
- 300 mm wide 42U frame fits standard row layouts
- 2,950 CFM airflow with active DX cooling targets hot spots
- 7-inch colour touchscreen gives instant status and alerts
Specifications
| Brand | Tripp Lite by Eaton |
|---|---|
| Part Number | SRCOOLDXRW25 |
| Type | Air Conditioners |
| Color | Black |
| Specifications | INPUT Electrical Consumption (Max): 10 kW Nominal Input Voltage(s) Supported: 208V AC Nominal Input Voltage Description: 208V AC 60 Hz Maximum Input Amps: 27 Input Connection Type: 3-wire / 4-wire + Ground Input Plug Features: 3-wire / 4-wire + Ground Voltage Compatibility (VAC): 208 Input Frequency: 60 Hz OUTPUT Frequency Compatibility: 60 Hz COOLING Airflow: 2,950 CFM Cooling Type: Active Cooling Capacity (BTUs): 88000 Cooling Capacity (kW): 25.8 Refrigerant: R410a (Environmentally friendly, Non ozone depleting) Refrigerant Amount: 17.4 lb. / 8.0 kg (Nominal) USER INTERFACE, ALERTS |
| Features | Slim Air Conditioning System Saves Space While Delivering Primary Precision Cooling Uses DX Technology to Deliver Cool Air to Loads High Cooling Efficiency Saves You Money Inverter compressor and EC fan technology automatically regulate cooling output to match heat load and conserve energy during off-peak hours, lowering your overall energy costs and lengthening the lifespan of the equipment being cooled. Easy to Operate with the Color Touchscreen Reconfigure Your Cooling Needs as Your Equipment Needs Change The modular, in-row cabinet design easily facilitates expansion or movement |
| Shipping weight | 199.58 kg |
| Package size | 2280 × 1245 × 1041 mm |
Questions about this item
How loud is the SRCOOLDXRW25 when it runs continuously in a data centre aisle?
The unit produces 68 dBA of audible noise during operation, which is comparable to a busy office environment and typical for in-row precision cooling equipment.
What electrical supply must already be in place for this 25.8 kW cooling system to operate?
A three-phase 208 V AC 60 Hz service capable of delivering up to 27 A with a 3-wire or 4-wire plus ground connection is required.
Will the SRCOOLDXRW25 fit alongside my existing 42U server racks without raising the row height?
Yes, the chassis is 42U tall and 300 mm wide, matching standard rack height so it aligns flush with 42U cabinets in the same row.
New to this? Buying server hardware with crypto — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.



