Delivers 12.8 kW precision cooling in a 300 mm wide, 42U rack for 208 V three-phase power
- TypeAir Conditioners
- ColorBlack
- SpecificationsINPUT Electrical Consumption (Max): 4800 Watts Nominal Input
- FeaturesSlim Air Conditioning System Saves Space While Delivering Pr
- Saves floor space with a 300mm wide 42U rack footprint
- Delivers 12.8 kW precision cooling for high-density server loads
- Inverter compressor and EC fans cut power draw to 4800 W maximum
- 1475 CFM airflow maintains consistent temperatures across the cabinet
- R410a refrigerant with 5.0 kg charge meets environmental standards
Precision In-Row Cooling
The Tripp Lite SRCOOLDXRW12 is a 12.8 kW precision cooling unit built for 42U server racks. It targets data-centre operators who need active, high-density heat removal in a 300 mm wide footprint. The system delivers 43,686 BTU/hr using DX technology with an inverter compressor and EC fans. It suits environments that demand consistent temperature control for critical IT loads.
Slim Rack Integration
A black aluminium and steel chassis houses the cooling assembly, fitting directly into standard row layouts without extra floor space. The unit draws a maximum of 4,800 W at 208 V AC three-phase, with a 16 A input rating and 3-wire or 4-wire plus ground connection. Front airflow reaches 1,475 CFM while audible noise measures 68 dBA. A 7-inch colour touchscreen on the front panel provides local monitoring and alerts.
Operational Range & Refrigerant
The unit operates from -4 °C to 46 °C ambient temperature and 5 % to 80 % humidity, with storage tolerance down to -40 °C and up to 60 °C. It is rated for elevations up to 4,000 m. R410a refrigerant is factory charged at 12.1 lb (5.0 kg), offering non-ozone-depleting performance. Facilities needing alternative voltages, redundant power inputs or water-cooled condensation will need a different solution.
Highlights
- Saves floor space with a 300mm wide 42U rack footprint
- Delivers 12.8 kW precision cooling for high-density server loads
- Inverter compressor and EC fans cut power draw to 4800 W maximum
- 1475 CFM airflow maintains consistent temperatures across the cabinet
- R410a refrigerant with 5.0 kg charge meets environmental standards
Specifications
| Brand | Tripp Lite by Eaton |
|---|---|
| Part Number | SRCOOLDXRW12 |
| Type | Air Conditioners |
| Color | Black |
| Specifications | INPUT Electrical Consumption (Max): 4800 Watts Nominal Input Voltage(s) Supported: 208V AC Nominal Input Voltage Description: 208V AC 60 Hz Maximum Input Amps: 16 Input Connection Type: 3-wire / 4-wire + Ground Input Plug Features: 3-wire / 4-wire + Ground Voltage Compatibility (VAC): 208 Input Frequency: 60 Hz OUTPUT Frequency Compatibility: 60 Hz COOLING Airflow: 1,475 CFM Cooling Type: Active Cooling Capacity (BTUs): 43686 Cooling Capacity (kW):12.8 Refrigerant: R410a (Environmentally friendly, Non ozone depleting) Refrigerant Amount: 12.1 lb. / 5.0 kg (Nominal) USER INTERFACE, AL |
| Features | Slim Air Conditioning System Saves Space While Delivering Primary Precision Cooling Uses DX Technology to Deliver Cool Air to Loads High Cooling Efficiency Saves You Money Inverter compressor and EC fan technology automatically regulate cooling output to match heat load and conserve energy during off-peak hours, lowering your overall energy costs and lengthening the lifespan of the equipment being cooled. Easy to Operate with the Color Touchscreen Reconfigure Your Cooling Needs as Your Equipment Needs Change The modular, in-row cabinet design easily facilitates expansion or movement |
| Shipping weight | 185.97 kg |
| Package size | 2280 × 1245 × 1041 mm |
Questions about this item
What voltage and phase does the SRCOOLDXRW12 require, and what is the maximum current draw?
The unit operates on 208V AC three-phase power at 60 Hz and draws a maximum of 16 amps.
What rack height and width are needed to mount this 300 mm in-row cooling system?
It fits a standard 42U server rack and occupies a 300 mm wide enclosure.
How is the SRCOOLDXRW12 configured on site, and what step is often missed during commissioning?
Configuration is done through the 7-inch colour touchscreen; the step often missed is setting the refrigerant charge to the nominal 12.1 lb (5.0 kg) before starting the inverter compressor.
New to this? Buying server hardware with crypto — what to check, what it costs to pay, and what is never asked for.