Tripp Lite
Tripp Lite PDUV30 PDU 24x 5-15/20R L5-30P 2.9kW 120V 10ft 63.75in 0U
Distributes 120 V power to 24 NEMA 5-15/20R outlets via a 10 ft L5-30P cord, with dual 20 A breakers and 0U vertical rack mounting
- TypeBasic
- Distributes 2.9 kW across 24 NEMA 5-15/20R outlets
- Dual 20 A breakers protect against overload damage
- Switchless design prevents accidental shutdowns
- Mounts vertically in 19-inch racks with included hardware
- 10-foot L5-30P cord connects to facility power
Ideal for Rack Power Distribution
This basic PDU distributes single-phase 120V power to 24 NEMA 5-15/20R outlets across two breakered load banks. It connects via a 10-foot cord with an L5-30P plug to a facility source, generator or UPS. The unit supports a 2.9kW capacity for networking, telecom and AV equipment in data centers or network closets.
Tool-Free Vertical Mounting
The 63.75-inch 0U form factor mounts vertically in a 19-inch EIA rack using included toolless buttons or brackets with user-supplied hardware. A switchless design prevents accidental shutdowns while dual 20A circuit breakers protect against overloads. Bolt-down retention brackets keep power cords organised during installation.
Verify Input and Rack Compatibility
Confirm your facility provides a compatible NEMA L5-30P receptacle for the input plug. Ensure the rack or mounting surface accommodates the 63.75-inch vertical length and 0U footprint. Check that connected equipment uses NEMA 5-15/20P plugs and that total draw stays within the 2.9kW rating.
Highlights
- Distributes 2.9 kW across 24 NEMA 5-15/20R outlets
- Dual 20 A breakers protect against overload damage
- Switchless design prevents accidental shutdowns
- Mounts vertically in 19-inch racks with included hardware
- 10-foot L5-30P cord connects to facility power
Specifications
| Brand | Tripp Lite |
|---|---|
| Type | Basic |
| Shipping weight | 4.54 kg |
| Package size | 348 × 135 × 104 mm |
Questions about this item
How can I confirm the PDUV30 is distributing power correctly after installation?
Verify that connected equipment powers on normally and the dual 20A circuit breakers remain in the ON position without tripping under load.
What accessories are included with the PDUV30 and what must I provide separately?
The unit includes toolless mounting buttons and mounting brackets; user-supplied hardware is required for bracket installation and counter mounting.
Which version of this PDU should I select for a 120V 30A rack circuit?
The PDUV30 with NEMA L5-30P input plug and 2.9kW capacity is designed for 120V 30A single-phase circuits.