Tripp Lite PDUV30-36 12-Outlet PDU 120V 30A 36in 0U Vertical Rack-mountable
A 120V basic PDU distributes power through twelve NEMA 5-15/20R outlets from a NEMA L5-30P input, with dual 20A breakers and a 10-foot cord, mounting vertically in a 19-inch rack
- TypeBasic
- Delivers network-grade 120V power to 12 outlets
- Switchless design prevents accidental shutdowns during operation
- Dual 20A circuit breakers protect against dangerous overloads
- 36-inch 0U form factor fits vertical EIA 19-inch racks
- 10-foot cord with NEMA L5-30P plug connects to facility power
12-Outlet 120V Vertical PDU
This 0U power distribution unit delivers twelve NEMA 5-15/20R outlets from a single NEMA L5-30P input. It is built for network closets, data centres and telecom racks that need reliable 120V distribution without monitoring features. The vertical form factor preserves horizontal rack space for servers and switches.
Replaces basic power strips in 19-inch racks
A 10-foot cord with a locking 30A plug connects to facility power or a UPS output. Dual 20A breakers protect each six-outlet bank from overloads. The upgrade is worth it when you need switchless operation to prevent accidental shutdowns and bolt-down cord retention for cable management.
Toolless buttons or brackets mount in seconds
Included mounting buttons snap into EIA 19-inch rack holes without tools. Brackets are also supplied for under-counter or wall attachment using your own hardware. The only common issue is forgetting to supply the two screws needed for bracket installations.
Highlights
- Delivers network-grade 120V power to 12 outlets
- Switchless design prevents accidental shutdowns during operation
- Dual 20A circuit breakers protect against dangerous overloads
- 36-inch 0U form factor fits vertical EIA 19-inch racks
- 10-foot cord with NEMA L5-30P plug connects to facility power
Specifications
| Type | Basic |
|---|---|
| Shipping weight | 3.15 kg |
| Package size | 940 × 127 × 102 mm |
Questions about this item
Will the 36-inch 0U PDU fit inside my EIA-standard 19-inch rack?
Yes, the 36-inch vertical chassis is designed to mount in an EIA-standard 19-inch rack using the included toolless buttons or brackets.
How do I install the unit, and what step is commonly missed?
Mount the PDU vertically with the supplied toolless buttons or brackets, then secure cords with the bolt-down retention brackets — a step often skipped.
When will the dual 20A circuit breakers need attention?
The dual 20A breakers protect each six-outlet load bank; reset them only after removing the overload that caused the trip.