We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Tripp Lite

Tripp Lite PDUV1548 0U PDU 120V 1.44kW 16x 5-15R 5-15P 48in

SKU CH-RVPD-DBB11 MPN PDUV1548

Distributes 120 V power to sixteen NEMA 5-15R outlets from a 15 A input with a 15-foot cord, mounting vertically in a 19-inch rack or on a wall

  • TypeBasic
  • Rack Size0U
  • StyleVertical
  • Input Voltage120V AC
  • Maximum Input Current15A
  • Regulatory Derated Input Current12A
  • 16 NEMA 5-15R outlets power multiple devices from one source
  • 15 A circuit breaker protects connected equipment from overloads
  • 15 ft input cord with 5-15P plug reaches distant power sources
  • 0U vertical design mounts in 19 in racks using included hardware
  • 44 kW capacity at 120 V supports networking and telecom loads

Vertical 0U PDU with 16 outlets

The Tripp Lite PDUV1548 is a basic power distribution unit that delivers 120V AC power to rack-mounted equipment. It provides 16 NEMA 5-15R outlets fed by a 15-foot cord with a NEMA 5-15P plug. The unit supports a maximum output of 1440W at a derated input current of 12A.

Suits racks needing simple outlet expansion

This PDU fits network closets, server rooms and AV racks where only unmonitored power distribution is required. The 48-inch vertical form factor mounts in a 19-inch rack without using horizontal rack units. Buyers who need outlet-level monitoring, switched outlets or input voltages other than 120V should consider other options.

15A circuit breaker protects connected loads

A single 15A circuit breaker provides overload protection for all 16 outlets. The lighted on/off switch includes a transparent cover to prevent accidental shutdowns. This breaker rating is the key specification that determines whether the PDU can handle the combined draw of your connected devices.

Highlights

  • 16 NEMA 5-15R outlets power multiple devices from one source
  • 15 A circuit breaker protects connected equipment from overloads
  • 15 ft input cord with 5-15P plug reaches distant power sources
  • 0U vertical design mounts in 19 in racks using included hardware
  • 44 kW capacity at 120 V supports networking and telecom loads

Specifications

BrandTripp Lite
ModelPDUV15-48
Part NumberPDUV15-48
TypeBasic
Rack Size0U
StyleVertical
Input Voltage120V AC
Maximum Input Current15A
Regulatory Derated Input Current12A
Input Connector(s)NEMA 5-15P
Cord Length15 ft.
Output Voltage120V AC
Output Watts (VA)1440W (1.4 kW)
Output Connector(s)16 x NEMA 5-15R
Maximum Output Current15A
Overload Protection15A Circuit Breaker
Shipping weight2.27 kg
Package size1305 × 82 × 60 mm

Questions about this item

How can I confirm the PDU is distributing power correctly after mounting it in the rack?

Verify the lighted on/off switch is illuminated and connected equipment powers on without tripping the 15A circuit breaker.

What mounting hardware is included and what must I source separately for a standard 19-inch rack installation?

The package includes toolless mounting buttons plus clips and hardware for 19-inch EIA racks; no extra rack hardware is required.

Which input current rating should I plan for — the 15A maximum or the 12A derated value — when sizing the upstream circuit?

Design the upstream circuit for the regulatory derated input current of 12A to stay within continuous-load limits.