Tripp Lite
Tripp Lite PDUNVR30HVLX Monitored PDU 24 Outlets 208/240V 5.8kW L6-30P
A monitored PDU with 24 outlets delivering 5.8 kW at 208/240 V, featuring real-time per-outlet power metering and remote network management
- TypeMonitored
- Monitored PDU enables real-time remote voltage and load tracking via built-in network interface
- 24 outlets (20 C13 and 4 C19) distribute 208/240V power across two breakered load banks
- 8kW single-phase capacity supports high-density rack equipment in data centers and network closets
- Per-outlet metering provides 1% billing-grade power consumption data for each connected device
- LX Platform network management card delivers Java-free HTML5 remote access 24/7
24-Outlet Monitored PDU
The Tripp Lite PDUNVR30HVLX is a 24-outlet monitored power distribution unit built for 208/240V single-phase supplies. It delivers up to 5.8kW through an L6-30P inlet and is suited for small-to-mid-sized data centres or high-density network closets.
LX Platform Network Management
A built-in LX Platform network card provides Java-free HTML5 remote access 24/7. It enables real-time monitoring of voltage, frequency, input current and per-outlet output current with 1% billing-grade accuracy across two breakered load banks.
20 C13 and 4 C19 Outlets
Twenty C13 and four C19 outlets distribute power to rack equipment while per-outlet metering reveals device-level consumption trends. The 30 A inlet and 5.8 kW rating set the total headroom; loads beyond that require additional distribution units.
Highlights
- Monitored PDU enables real-time remote voltage and load tracking via built-in network interface
- 24 outlets (20 C13 and 4 C19) distribute 208/240V power across two breakered load banks
- 8kW single-phase capacity supports high-density rack equipment in data centers and network closets
- Per-outlet metering provides 1% billing-grade power consumption data for each connected device
- LX Platform network management card delivers Java-free HTML5 remote access 24/7
Specifications
| Type | Monitored |
|---|---|
| Shipping weight | 10.43 kg |
| Package size | 1930 × 170 × 145 mm |
Questions about this item
What maintenance or replacement will the internal LX Platform network management card need later?
The built-in LX Platform card is integrated into the PDU and has no user-serviceable parts; if it fails the entire unit would require service.
Which limit appears first on the two breakered load banks during sustained full-load operation?
Each load bank is protected by its own breaker, so the 30 A input rating on the L6-30P plug will trip before any single bank exceeds its share of the 5.8 kW capacity.
How much heat and fan noise does the PDU produce when running continuously at 5.8 kW?
The PDU has no internal fans and operates silently; all heat comes from normal conduction through the breakers and outlet contacts at the rated 5.8 kW load.