Tripp Lite
Tripp Lite PDUMNH20HVAT PDU 3.3/3.8kW 208/240V L6-20R 2 L6-20P 1U
A monitored 1U rack PDU with automatic transfer switching between two 20 A inputs and a single L6-20R output for redundant power delivery
- TypeMonitored
- Rack Size1U
- StyleHorizontal
- Front Panel LEDsFront panel LEDs confirm amp (A) / kilowatt (kW) / voltage (
- CertificationsTested to UL/CSA 60950-1 (USA, Canada), FCC Class A (Emissio
- ROHSYes
- Automatic transfer switching within 1–5 ms protects connected equipment from power interruptions
- Ethernet network interface enables remote monitoring of voltage, current, power factor and frequency
- Single L6-20R outlet delivers 3.3/3.8 kW to a device or 0U vertical PDU
- Dual L6-20P inputs with 10 ft cords provide redundant 200–240 V power sources
- 1U horizontal rack-mount design fits standard cabinets and operates at 0–50 °C
1U Monitored ATS PDU
This is a 1U rack-mount monitored power distribution unit with automatic transfer switching. It accepts two L6-20P inputs with 10 ft cords and provides a single L6-20R output. The unit operates at 200 to 240V single-phase with a maximum input current of 20A and delivers 3.3 to 3.8kW capacity. Front-panel LEDs display real-time amperage, kilowatt, voltage, frequency and power factor readings.
IT environments needing redundant single-phase power
Network managers and data-centre operators who need fast failover between two 20A feeds will benefit from the 1–5 ms transfer time and Ethernet remote monitoring. Builders requiring multiple output receptacles or three-phase distribution should consider a different PDU configuration. The single L6-20R outlet limits direct connections to one device or a downstream vertical PDU.
Automatic transfer within 1–5 ms
The defining specification is the 1–5 millisecond automatic transfer switching between the two L6-20P inputs. This speed maintains continuous power to connected equipment during source failures. The monitored Ethernet interface adds remote visibility of load, voltage and power factor without requiring a local display.
Highlights
- Automatic transfer switching within 1–5 ms protects connected equipment from power interruptions
- Ethernet network interface enables remote monitoring of voltage, current, power factor and frequency
- Single L6-20R outlet delivers 3.3/3.8 kW to a device or 0U vertical PDU
- Dual L6-20P inputs with 10 ft cords provide redundant 200–240 V power sources
- 1U horizontal rack-mount design fits standard cabinets and operates at 0–50 °C
Specifications
| Brand | Tripp Lite |
|---|---|
| Model | PDUMNH20HVAT |
| Type | Monitored |
| Rack Size | 1U |
| Style | Horizontal |
| Front Panel LEDs | Front panel LEDs confirm amp (A) / kilowatt (kW) / voltage (V) / frequency (Hz) and power factor (PF) reporting information; Additional set of LEDs indicate Source A and Source B inputs for preferred, available and in-use status |
| Certifications | Tested to UL/CSA 60950-1 (USA, Canada), FCC Class A (Emissions), NOM (Mexico) |
| ROHS | Yes |
| Package Includes | PDUMNH20HVAT 3.3/3.8kW Single-Phase 208/240V ATS/Monitored PDU Mounting brackets Owner's manual |
| Input Voltage | 200V; 208V; 220V; 230V; 240V |
| Maximum Input Current | 20A |
| Input Connector(s) | NEMA L6-20P |
| Cord Length | 10 ft |
| Output Voltage | 240V, 230V, 220V, 208V, 200V |
| Output Frequency | 50/60Hz |
| Output Connector(s) | 1 x L6-20R |
| Operating Environment | 0 - 50 degrees C |
| Operating Relative Humidity | 5 - 95% |
| Operating Elevation | 0 - 3000 m |
| Storage Temperature | -15 - 60 degrees C |
| Features | Primary and Secondary Inputs for Power Redundancy Built-In L6-20R Outlet Automatic Transfer Switching (ATS) Multifunction Digital Display Advanced Network Monitoring Broad Communications Compatibility Mounts Horizontally in 1U of Rack Space |
| Dimensions | 1.72" x 16.93" x 14.00" |
| Weight | 15.37 lbs. |
| Shipping weight | 7.58 kg |
| Package size | 559 × 533 × 254 mm |
Questions about this item
What does the 1U PDU ship with and what must I provide separately?
The package includes the PDU, mounting brackets and owner's manual; you must supply a rack or cabinet for horizontal mounting and the equipment that plugs into the single L6-20R outlet.
How do the 3.3 kW and 3.8 kW ratings differ and which should I select?
3.3 kW is the maximum at 208 V and 3.8 kW at 240 V; choose based on the voltage your facility delivers — both inputs accept 200–240 V.
What does the 1–5 ms automatic transfer switching mean for my connected load?
If the preferred input fails, the PDU switches to the alternate source within 1–5 ms, keeping a single device or downstream PDU powered without interruption.