We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Tripp Lite

Tripp Lite PDUMNH20 1.9kW 120V 20A 8x5-15/20R 1U PDU

SKU CH-WCVA-469CN MPN PDUMNH20

Monitored 1.9 kW PDU delivers 120 V power to eight 5-15/20R outlets with Ethernet reporting and a front-panel current meter

  • TypeMonitored
  • Rack Size1U
  • StyleHorizontal
  • CertificationsTested to UL 60950 (USA), CSA (Canada), Class A (Emissions),
  • Input Voltage100; 120; 127
  • Maximum Input Current20A
  • Monitored 1.9 kW capacity via Ethernet interface
  • Local digital display shows 16 A continuous load
  • 8 NEMA 5-15/20R outlets with retention brackets
  • 12 ft cord with L5-20P and 5-20P adapter
  • 1U horizontal rackmount fits standard 17.30" width

Monitored 1.9 kW PDU

The Tripp Lite PDUMNH20 is a monitored power distribution unit rated for 1.9 kW at 120 V with a 20 A input. It fits a 1U horizontal rack slot and provides eight NEMA 5-15/20R outlets for IT equipment. The unit includes a 12 ft cord with an L5-20P plug and a 5-20P adapter. It is suited for network closets and server rooms that need remote load visibility.

Input power and rack space

Verify that the facility can supply a 120 V single-phase circuit rated for 20 A with an L5-20R receptacle or a 5-20R receptacle for the included adapter. The continuous load must not exceed 16 A per agency derating. Confirm 1U of horizontal rack clearance and that the 12 ft cord reaches the power source without strain.

Thermal and electrical behaviour

The PDU operates up to 95 % relative humidity non-condensing and at elevations up to 10,000 ft. Storage temperature range spans 5 to 122 degrees Fahrenheit. The front-panel digital meter displays real-time current draw, while the built-in network interface reports voltage, frequency and load level remotely. No moving parts are present, so acoustic output is negligible.

Highlights

  • Monitored 1.9 kW capacity via Ethernet interface
  • Local digital display shows 16 A continuous load
  • 8 NEMA 5-15/20R outlets with retention brackets
  • 12 ft cord with L5-20P and 5-20P adapter
  • 1U horizontal rackmount fits standard 17.30" width

Specifications

BrandTripp Lite
ModelPDUMNH20
TypeMonitored
Rack Size1U
StyleHorizontal
CertificationsTested to UL 60950 (USA), CSA (Canada), Class A (Emissions), NOM (Mexico), RoHS compliant, TAA Compliant
Input Voltage100; 120; 127
Maximum Input Current20A
Input Connector(s)Attached L5-20P input cable plus 5-20P adapter
Cord Length12 ft
Output Voltage100; 120; 127
Output Frequency50/60Hz
Output Connector(s)8 x 5-15 / 20R
Operating Relative HumidityUp to 95% (non-condensing)
Operating Elevation0 - 10,000 ft (0 - 3000 m)
Storage Temperature5 to 122 degrees Fahrenheit (-15 to 50 degrees Celsius)
Features120V 20A peak capacity (agency de-rated to 16 amps continuous) Monitored Power Distribution Unit (PDU) with built-in web/network interface in 0U vertical rack form factor
Includes attached L5-20P input plug with 5-20P adapter and 8 5-15/20R outlets
Supports local current metering and remote network monitoring of current, voltage and frequency via built-in web/network monitoring card
Remote interface provides data regarding input power conditions and PDU load level via secure network or web browser interface
Supports notification and logging of all major power events and user specifie
Dimensions1.70" x 17.30" x 6.20"
Weight7.00 lbs.
Shipping weight4.14 kg
Package size521 × 279 × 265 mm

Questions about this item

What comes in the box with the PDUMNH20 and is anything else required for installation?

The unit ships with an attached L5-20P input cable, a 5-20P adapter, and cord retention brackets for the eight outlets. No extra parts are needed for basic rack mounting.

Should I choose the L5-20P plug or the 5-20P adapter for my 20 A circuit?

Use the attached L5-20P plug for a locking NEMA L5-20R receptacle; snap on the included 5-20P adapter only if your facility provides a straight-blade 5-20R outlet.

What does the 1.9 kW rating mean for continuous load on this PDU?

Agency rules de-rate the 20 A input to 16 A continuous, so the practical maximum is 1.9 kW at 120 V; the front meter and web interface show real-time amperage to keep you below that limit.