We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Tripp Lite

Tripp Lite PDUMH20HVATS Switched Metered ATS PDU 200-240V 8 C13 2 C19 Dual C20 12ft 1U

SKU CH-015F-SKZ8M MPN PDUMH20HVATS

A switched metered PDU with automatic transfer switching in under 5 ms, ten IEC outlets and dual 12 ft input cords for 200–240 V redundant power

  • TypeSwitched, Metered
  • StyleHorizontal
  • CertificationsTested to UL 60950 (USA, Canada), CE (Europe), Class A (Emis
  • Package IncludesPDUMH20HVATS 3.8kW Single-Phase ATS/Metered PDU (2) Detachab
  • Input Voltage200 - 240V
  • Maximum Input Current20A
  • Redundant power with
  • Real-time load monitoring via built-in digital ammeter
  • Ten IEC outlets: eight C13 and two C19
  • Dual 12 ft input cords for separate power feeds
  • TAA compliant for GSA Schedule procurement

Power Redundancy for Rack Equipment

The Tripp Lite PDUMH20HVATS is a switched, metered automatic transfer switch PDU built for 1U horizontal rack mounting. It accepts dual 200–240V inputs and distributes power across ten locking outlets, giving single-corded servers and network gear a path to redundant supply without internal changes.

Horizontal Build with Locking Outlets

The 1.72-inch tall chassis fits standard 19-inch racks and includes mounting hardware for quick installation. Two detachable 12-foot C19-to-C20 cords connect to separate primary and secondary sources, while eight C13 and two C19 outlets secure attached plugs with supplied lock sleeves. A front-panel digital ammeter shows real-time load in amps, and sequential outlet turn-on at 250-millisecond intervals limits inrush at startup.

Upgrade from Basic Strip PDUs

This unit replaces unmetered, single-source power strips that cannot report load or fail over when a feed drops. The jump is worth it when equipment lacks dual power supplies but the site runs dual UPS or utility feeds, and when local current visibility is needed to avoid tripping a 20-amp branch circuit.

Highlights

  • Redundant power with
  • Real-time load monitoring via built-in digital ammeter
  • Ten IEC outlets: eight C13 and two C19
  • Dual 12 ft input cords for separate power feeds
  • TAA compliant for GSA Schedule procurement

Specifications

BrandTripp Lite
ModelPDUMH20HVATS
TypeSwitched, Metered
StyleHorizontal
CertificationsTested to UL 60950 (USA, Canada), CE (Europe), Class A (Emissions), NOM (Mexico), RETIE (Columbia), EAC (Russia), RoHS Compliant, TAA Compliant
Package IncludesPDUMH20HVATS 3.8kW Single-Phase ATS/Metered PDU
(2) Detachable C19 to C20 input cords, 12 ft. (3.7 m)
(10) Plug-lock insert sleeves
Rack-mounting hardware
Owner's manual
Input Voltage200 - 240V
Maximum Input Current20A
Cord Length12 ft
Output Voltage200; 208; 220; 230; 240
Output Frequency50/60Hz
Storage Temperature-30 °C to +50 °C (-22°F to +122°F)
Storage Relative Humidity5 - 95%
FeaturesSingle-Phase 20A ATS PDU Distributes and Monitors Network-Grade Power in Real Time
This metered PDU provides real-time local reporting of the total load level via its built-in digital current meter. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMH20HVATS features eight C13 and two C19 200-240V outlets for connecting equipment. Outlets are factory-programmed for sequential turn-on at 250-millisecond intervals when the PDU is first energized to prevent inrush-related equipment interaction at startup.
Switches from Primary to Secon
Dimensions1.72" x 17.30" x 14.80"
Weight10.30 lbs.
Shipping weight8.07 kg
Package size589 × 528 × 137 mm

Questions about this item

What input voltage range does the dual C20 inlet support and what is the maximum current?

The PDU accepts 200–240V at up to 20A through its two C20 inlets.

What rack space and mounting depth does the 1U chassis require?

It occupies 1U height, 17.30in wide and 14.80in deep, and includes rack-mounting hardware.

How do you connect the two 12ft input cords for automatic transfer switching?

Plug each C19-to-C20 cord into a separate primary and secondary source; the unit switches in under 5ms.