Tripp Lite
Tripp Lite PDUMH20ATNET 1.9 kW 120V 20A 1U Switched PDU 16 Outlets
Distributes 1.9 kW at 120 V across 16 switched NEMA 5-15/20R outlets with dual L5-20P or 5-20P inputs and network monitoring in a 1U rackmount
- TypeSwitched
- Rack Size1U
- CertificationsTested to UL 60950 (USA, Canada), Class A (Emissions), NOM (
- ROHSYes
- Input Voltage120V
- Maximum Input Current20A
- Redundant A/B power protects single-corded devices with dual L5-20P and 5-20P inputs
- 16 individually switched NEMA 5-15/20R outlets enable remote power cycling per device
- 9 kW 120 V capacity supports 20 A maximum input current for dense loads
- Built-in LX Platform network interface and digital meter provide real-time current monitoring
- Tested to UL 60950 for USA and Canada with TAA and RoHS compliance
1U Switched PDU with 16 Outlets
The Tripp Lite PDUMH20ATNET is a 1U rackmount power distribution unit that provides 16 individually switched NEMA 5-15/20R outlets. It delivers a 1.9 kW capacity at 120V with a maximum input current of 20A. The unit includes a built-in LX Platform network interface for remote outlet control and digital current monitoring via a two-digit visual meter. It is suited for network administrators managing single-corded devices in server rooms or wiring closets.
Replaces Basic PDUs for Redundant Power
This unit replaces non-switched or non-metered PDUs when you need redundant A/B power input for equipment that has only a single power supply. The dual NEMA L5-20P inputs with included 5-20P adapters allow connection to two separate power sources, enabling automatic transfer switching. The jump is worth it when you require remote reboot capability for individual outlets and real-time load monitoring to prevent circuit overloads without visiting the rack.
Check Rack Space and Input Compatibility
Verify that your rack has 1U of vertical space measuring 1.75 inches in height and sufficient depth for the 14.50-inch chassis depth. Confirm your facility provides 120V service at 50/60Hz and that your upstream circuits can supply 20A per input cord. The 12.0-foot input cords with L5-20P connectors and 5-20P adapters must reach your power sources. Ensure the operating environment stays within 95% relative humidity non-condensing.
Highlights
- Redundant A/B power protects single-corded devices with dual L5-20P and 5-20P inputs
- 16 individually switched NEMA 5-15/20R outlets enable remote power cycling per device
- 9 kW 120 V capacity supports 20 A maximum input current for dense loads
- Built-in LX Platform network interface and digital meter provide real-time current monitoring
- Tested to UL 60950 for USA and Canada with TAA and RoHS compliance
Specifications
| Brand | Tripp Lite |
|---|---|
| Model | PDUMH20ATNET |
| Type | Switched |
| Rack Size | 1U |
| Certifications | Tested to UL 60950 (USA, Canada), Class A (Emissions), NOM (Mexico), RoHS Complaint |
| ROHS | Yes |
| Input Voltage | 120V |
| Maximum Input Current | 20A |
| Input Connector(s) | 2 x NEMA L5-20P with 2 x NEMA 5-20P plug adapters |
| Cord Length | 12.0 Feet |
| Output Voltage | 120V |
| Output Frequency | 50/60Hz |
| Output Connector(s) | 16 x NEMA 5-15/20R |
| Operating Relative Humidity | Up to 95% (non-condensing) |
| Features | 1U switched PDU with digital current monitoring, network interface and 16 individually controllable outlets 20A 120V capacity with 16 NEMA 5-15/20R outlets with support for L5-20P and 5-20P input connections Connects to NEMA 5-20R and locking L5-20R receptacle Optional Auto Transfer Switch (ATS) supports a variety of advanced fault-tolerant and redundant networking applications Supports 2 - 7 ms. transfer between included primary and secondary line cords, even with out of phase power sources |
| Dimensions | 1.75" x 17.50" x 14.50" |
| Weight | 12.20 lbs. |
| Shipping weight | 9.42 kg |
| Package size | 587 × 508 × 152 mm |
Questions about this item
What rack depth and height does the 1U PDUMH20ATNET need to mount?
It fits a standard 1U space measuring 1.75 inches high, 17.50 inches wide and 14.50 inches deep.
How are the dual 12.0-foot input cords connected for redundant power, and what mistake should be avoided?
Plug each NEMA L5-20P or 5-20P cord into separate A and B sources; do not connect both to the same circuit or you lose redundancy.
When should the internal current monitoring or network interface be checked or replaced?
Monitor the two-digit current meter and LX Platform alerts continuously; replace the unit if monitoring fails or outlets no longer switch reliably.