Tripp Lite
Tripp Lite PDUMH15HVATNET PDU Switched ATS 10 C13 2 C14 3.6 m 200-240V 1U
Switched ATS PDU provides redundant 200–240 V power to ten C13 outlets from dual C14 inputs with 3.6 m cords in a 1U rack mount
- TypeSwitched
- Rack Size1U
- StyleHorizontal
- Front Panel LEDs8 LEDs display power on-off status for each C13 output recep
- CertificationsTested to UL 60950-1 (USA, Canada), CE (EU), NOM (Mexico), G
- ROHSRoHS Complaint
- Switched outlets enable remote power cycling per receptacle
- Automatic transfer switching fails over between two C14 inputs in milliseconds
- Ten C13 outlets distribute up to 2.4 kW at 240 V
- Front-panel LEDs show status for every outlet and both inputs
- Horizontal 1U form factor fits standard racks with included brackets
Rack PDU with Automatic Transfer Switch
The Tripp Lite PDUMH15HVATNET is a switched 1U horizontal power distribution unit designed for server racks that require redundant power feeds. It accepts two IEC-320 C14 inputs and provides ten IEC-320 C13 outlets for connected equipment. Network management allows remote outlet control and monitoring. TAA compliance suits federal procurement requirements.
Thermal and Power Behaviour
The unit operates passively with no internal fans, so it adds no audible noise to the rack environment. It handles input voltages from 200 to 240 V at 50 or 60 Hz with a maximum input current of 10 A. Output capacity ranges from 2.0 kW at 200 V up to 2.4 kW at 240 V. Operating elevation is rated to 10000 feet and storage temperature spans -15 to 50 °C.
Build and Connectivity Practicalities
The steel chassis includes horizontal mounting brackets for standard 1U rack installation. Front-panel LEDs show power status for each of the ten C13 outlets plus both C14 inputs. Two locking C13-to-C14 cords measuring 3.6 m (11.8 ft) and ten C14 plug-lock inserts are supplied to prevent accidental disconnection. A configuration cable for the SNMPWEBCARD is also included.
Highlights
- Switched outlets enable remote power cycling per receptacle
- Automatic transfer switching fails over between two C14 inputs in milliseconds
- Ten C13 outlets distribute up to 2.4 kW at 240 V
- Front-panel LEDs show status for every outlet and both inputs
- Horizontal 1U form factor fits standard racks with included brackets
Specifications
| Brand | Tripp Lite |
|---|---|
| Model | PDUMH15HVATNET |
| Type | Switched |
| Rack Size | 1U |
| Style | Horizontal |
| Front Panel LEDs | 8 LEDs display power on-off status for each C13 output receptacle, plus 2 additional LEDs to indicate input power status for primary and secondary inputs |
| Certifications | Tested to UL 60950-1 (USA, Canada), CE (EU), NOM (Mexico), GOST (Russia), EN55032:2015 and EN62040-2:2006, FCC Class A (Emissions), TAA Compliant |
| ROHS | RoHS Complaint |
| Package Includes | PDUMH15HVATNET TAA-Compliant 2 - 2.4k Watts Single-Phase ATS / Switched PDU 10 x C14 plug lock inserts 2 x C13 to C14 power cords, 3.6 m(11.8 Feet) SNMPWEBCARD configuration cable 2 x Mounting brackets, horizontal 2 x Mounting brackets, vertical 6 x Screws Owner’s manual |
| Input Voltage | 200 - 240V |
| Maximum Input Current | 10A |
| Input Connector(s) | IEC-320 C14 |
| Cord Length | 12 ft |
| Output Voltage | 200; 208; 220; 230; 240 V |
| Output Frequency | 50/60Hz |
| Output Watts (VA) | 2.4k Watts (240V), 2.3k Watts (230V), 2.2k Watts (220V), 2.08k Watts (208V), 2.0k Watts (200V) |
| Output Connector(s) | 10 x C13 |
| Operating Elevation | 0 - 10000 Feet |
| Storage Temperature | -15 - 50 Celcius degree |
| Storage Relative Humidity | 5 - 95% |
| Features | Primary and Secondary Inputs for Power Redundancy Provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations Dual 3.6 m input cords with IEC-320 C14 plugs connect to separate primary and secondary single-phase power sources 8 switched and 2 unswitched C13 outlets Automatic Transfer Switching Dynamic solid-state(TRIAC) automatic transfer switching Switches to secondary power source if primary source fails or becomes unstable 2 - 5 ms transfer time ensures uninterrupted operation of connected equipment Built-in proces |
| Dimensions | 1.71" x 17.33" x 14.45" |
| Weight | 10.41 lbs. |
| Shipping weight | 7.10 kg |
| Package size | 580 × 515 × 110 mm |
Questions about this item
How do I rack-mount the PDUMH15HVATNET and secure the C13 outputs so they don't pull loose?
Use the two included horizontal mounting brackets to fix the 1U unit in a standard rack, then insert the ten supplied C14 plug-lock inserts into each C13 receptacle before connecting equipment cords.
What components will need replacement during the PDUMH15HVATNET's service life?
The IEC-320 C14 input cords and C13 output cords are the only field-replaceable parts; the internal automatic transfer switch and switched outlet relays are not user-serviceable.
At what load does the PDUMH15HVATNET hit its input-current limit first during sustained operation?
The 10 A maximum input current is reached at 2.0 kW on a 200 V supply, 2.08 kW at 208 V, 2.2 kW at 220 V, 2.3 kW at 230 V, and 2.4 kW at 240 V.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.