Tripp Lite
Tripp Lite PDUMH15ATS PDU 120V 1.44kW 15A 8×5-15R Dual 5-15P 12ft
Metered 1U PDU with automatic transfer switching provides redundant 120V power to eight NEMA 5-15R outlets from dual 5-15P inputs
- TypeAuto-Transfer Switch; Metered
- Rack Size1U
- StyleHorizontal
- CertificationsTested to UL 60950-1 (USA), CSA (Canada), Class A (Emissions
- Package IncludesATS / Metered PDU with attached 5-15P primary input cord Det
- Input Voltage120V
- Automatic transfer switching keeps equipment running during source failure
- Built-in digital meter displays real-time load in amps
- Eight NEMA 5-15R outlets power multiple devices from one unit
- Dual 12 ft input cords connect to separate A and B sources
- TAA compliant for government procurement schedules
1U ATS Metered PDU
The Tripp Lite PDUMH15ATS is a 1U horizontal rackmount power distribution unit that provides an automatic transfer switch for single-corded network equipment. Dual NEMA 5-15P inputs connect to separate power sources and the unit switches automatically if the primary source fails. Eight NEMA 5-15R outlets distribute 120V power to connected devices. A two-digit current meter displays the aggregate load in amps.
Thermals noise and power draw
The PDU operates within a storage temperature range of -15°C to +50°C and tolerates 5 to 95 percent relative humidity in storage. Agency de-rating limits continuous current to 12A, delivering up to 1.44kW at 120V, 1.52kW at 127V, or 1.2kW at 100V. No active cooling fans are present so the unit adds no audible noise to the rack environment. Power passes through without conversion losses beyond the switching circuitry.
Build integration needs
The package includes a 12 ft attached primary cord and a detachable 3.6 m secondary cord with C13 to NEMA 5-15P connectors. Standard 1U rackmount brackets mount the 1.75 by 17.50 by 14.50 inch chassis weighing 11.00 lbs in any compatible rack. TAA compliance qualifies the unit for GSA schedule purchases. The ATS function frees single-corded devices from needing dual power supplies while the meter frees administrators from guessing circuit load.
Highlights
- Automatic transfer switching keeps equipment running during source failure
- Built-in digital meter displays real-time load in amps
- Eight NEMA 5-15R outlets power multiple devices from one unit
- Dual 12 ft input cords connect to separate A and B sources
- TAA compliant for government procurement schedules
Specifications
| Brand | Tripp Lite |
|---|---|
| Model | PDUMH15ATS |
| Type | Auto-Transfer Switch; Metered |
| Rack Size | 1U |
| Style | Horizontal |
| Certifications | Tested to UL 60950-1 (USA), CSA (Canada), Class A (Emissions), NOM (Mexico), RoHS Compliant, TAA Compliant |
| Package Includes | ATS / Metered PDU with attached 5-15P primary input cord Detachable C13 to NEMA 5-15P 12 ft / 3.6m secondary input cord 1U rackmount installation brackets User manual with warranty information |
| Input Voltage | 120V |
| Maximum Input Current | 15A |
| Cord Length | 12 ft |
| Output Voltage | 100; 120; 127 |
| Output Frequency | 50/60Hz |
| Output Watts (VA) | 1.52kW (127V), 1.44kW (120V), 1.2kW (100V) |
| Storage Temperature | -15°C to +50°C (-22°F to +122°F) |
| Storage Relative Humidity | 5 - 95% |
| Features | Federal Trade Agreements Act / TAA compliant for GSA schedule purchases. 120V 15A Automatic Transfer Switch (ATS) / Metered PDU (Agency de-rated to 12A continuous). Provides a redundant A/B power option for non-redundant networking equipment with a single input power cord. Digital display continuously reports total output power consumption in amps. 1U horizontal rackmount form factor; 14.5 in. / 36.8 cm depth. 8 built-in NEMA 5-15R outlets. Set of two 12 ft. / 3.6m NEMA 5-15P input cables support connection to separate PRIMARY and SECONDARY power sources. |
| Dimensions | 1.75" x 17.50" x 14.50" |
| Weight | 11.00 lbs. |
| Shipping weight | 7.74 kg |
| Package size | 592 × 528 × 135 mm |
Questions about this item
How do I install the PDUMH15ATS in a rack, and which step do people get wrong?
Mount the 1U horizontal unit using the included brackets, then plug the attached primary 5-15P cord and the detachable secondary 5-15P cord into two separate 120V 15A sources; the step often missed is ensuring both input circuits are on different phases or panels for true redundancy.
What maintenance or replacement will this PDU need later?
The unit has no user-serviceable parts; plan to replace the entire PDU if the auto-transfer switch or meter fails, and verify the 12A continuous de-rating is not exceeded during load changes.
What limit appears first under sustained load on the PDUMH15ATS?