Tripp Lite
Tripp Lite PDUMH15AT PDU 15A 120V 8x5-15R 2x5-15P 12ft 1U
A metered 1U rackmount PDU with automatic transfer switching provides redundant power to eight NEMA 5-15R outlets from dual 12 ft NEMA 5-15P inputs at 120V 15A
- TypeMetered
- Rack Size1U
- StyleRackmount
- Front Panel LEDs8 front panel LEDs display power on / off status for each ou
- CertificationsTested to UL 60950-1 (USA), CSA (Canada), Class A (Emissions
- ROHSYes
- Metered display shows real-time amp draw for precise load monitoring
- Automatic Transfer Switch provides redundant power from two independent sources
- Eight NEMA 5-15R outlets distribute power to rack-mounted equipment
- Dual 12 ft input cords connect to separate A/B circuits for failover
- 1U horizontal form factor fits standard 2-post or 4-post racks
Metered PDU with Automatic Transfer Switch
The Tripp Lite PDUMH15AT is a 1U rackmount power distribution unit that provides metered 120V 15A output through eight NEMA 5-15R outlets. It features an Automatic Transfer Switch with dual 12 ft NEMA 5-15P input cords for redundant power sourcing. A digital display shows total current draw in amps.
Suited for single-corded network gear needing
This unit fits administrators who want to connect one power supply to two separate sources such as a UPS and utility feed. It is not suited for equipment requiring input voltages other than 100, 120 or 127V, total loads above 15A, or outlet types other than 5-15R. Sequential 250 ms outlet startup prevents inrush interaction.
15A metered capacity with dual 12 ft input cords
The single specification that decides fit is the 15A maximum input current at 120V across eight 5-15R outlets. Dual 12 ft cords enable primary and secondary connections to separate circuits. UL 60950-1, CSA, NOM, RoHS and TAA certifications cover compliance for North American rack installations.
Highlights
- Metered display shows real-time amp draw for precise load monitoring
- Automatic Transfer Switch provides redundant power from two independent sources
- Eight NEMA 5-15R outlets distribute power to rack-mounted equipment
- Dual 12 ft input cords connect to separate A/B circuits for failover
- 1U horizontal form factor fits standard 2-post or 4-post racks
Specifications
| Brand | Tripp Lite |
|---|---|
| Model | PDUMH15AT |
| Type | Metered |
| Rack Size | 1U |
| Style | Rackmount |
| Front Panel LEDs | 8 front panel LEDs display power on / off status for each outlet, plus 2 additional LEDs to indicate input power status for primary and secondary inputs |
| Certifications | Tested to UL 60950-1 (USA), CSA (Canada), Class A (Emissions), NOM (Mexico), RoHS compliant, TAA compliant |
| ROHS | Yes |
| Input Voltage | 100; 120; 127V |
| Maximum Input Current | 15A |
| Input Connector(s) | 2 x NEMA 5-15P |
| Cord Length | 12 ft |
| Output Voltage | 100; 120; 127V |
| Output Frequency | 60 Hz |
| Output Connector(s) | 8 x 5-15R |
| Operating Relative Humidity | Up to 95% (non-condensing) |
| Features | 120V 15A metered PDU system with Automatic Transfer Switch (ATS) Dual input cords, one attached (primary) and one optional-use detachable cord (secondary) Included cordsets support 5-15P plug-in connection Front panel digital ammeter displays power consumption in amps 8 built-in NEMA 5-15R output receptacles Optional ATS function enables setup for hot-swappable UPS maintenance bypass, dual UPS protection or dual AC input redundancy for critical single-corded network hardware (ATS function requires the use of a full time sine wave online UPS, like Tripp Lite's SmartOnline series) ATS |
| Dimensions | 1.75" x 17.50" x 14.50" |
| Weight | 11.00 lbs. |
| Shipping weight | 7.73 kg |
| Package size | 587 × 533 × 140 mm |
Questions about this item
Does the metered PDU have any user-replaceable parts such as fuses or batteries?
The unit is a metered PDU with Automatic Transfer Switch and no internal batteries; it has no user-replaceable fuses or modules, so no scheduled parts replacement is required.
What is the maximum continuous load the 15 A inputs can sustain before the circuit breaker trips?
Each NEMA 5-15P input is rated for 15 A at 120 V; the internal breaker will trip if total draw exceeds 15 A continuously.
How much audible noise does the 1 U rackmount PDU produce when both input cords are live?
The PDU has no fans or moving parts, so it runs silently; only a faint relay click may be heard during an automatic transfer event.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.