Tripp Lite
Tripp Lite PDUMH15 Metered PDU 15A 120V 13×5-15R 15 ft 1U
Metered 1U rackmount PDU delivers 15 A at 120 V through 13 NEMA 5-15R outlets with a 15 ft cord and digital current display
- TypeMetered
- Rack Size1U
- StyleHorizontal rackmount
- Front Panel LEDsDigital LED current monitor display
- CertificationsTested to UL60950-1 (USA) and CAN/CSA C22.2 No. 60950-1-03 (
- ROHSYes
- Digital LED display shows real-time current draw
- 13 NEMA 5-15R outlets distribute 15 A at 120 V
- 15 ft cord with NEMA 5-15P plug reaches distant power sources
- 1U horizontal rackmount fits standard 19-inch cabinets
- Tested to UL 60950-1 and CSA C22.2 No. 60950-1 for safety compliance
Tripp Lite 15A Metered PDU with Digital Display
The Tripp Lite PDUMH15 is a metered power distribution unit that delivers 15 amps at 120 volts through thirteen NEMA 5-15R outlets. A front-panel digital LED display shows real-time current draw so administrators can monitor load levels at a glance. It mounts in 1U of a standard 19-inch rack and includes a 15 ft cord with a NEMA 5-15P plug.
Ideal for 120V Racks Needing Load Visibility
This unit suits server rooms and network closets running on 120 V single-phase power where knowing the aggregate current is important for capacity planning. It is not suited for environments that require 20 A or higher input ratings, voltages other than 120 V, or outlet types other than NEMA 5-15R. The fixed 15 ft input cord may also limit placement in larger facilities.
15 A Maximum Input Current Rating
The 15 A breaker and 5-15P inlet define the total power budget available to all thirteen outlets. Exceeding this rating trips the overload protection, so the connected equipment must stay within the 15 A limit at 120 V.
Highlights
- Digital LED display shows real-time current draw
- 13 NEMA 5-15R outlets distribute 15 A at 120 V
- 15 ft cord with NEMA 5-15P plug reaches distant power sources
- 1U horizontal rackmount fits standard 19-inch cabinets
- Tested to UL 60950-1 and CSA C22.2 No. 60950-1 for safety compliance
Specifications
| Brand | Tripp Lite |
|---|---|
| Model | PDUMH15 |
| Type | Metered |
| Rack Size | 1U |
| Style | Horizontal rackmount |
| Front Panel LEDs | Digital LED current monitor display |
| Certifications | Tested to UL60950-1 (USA) and CAN/CSA C22.2 No. 60950-1-03 (Canada), RoHS Compliant |
| ROHS | Yes |
| Input Voltage | 120V |
| Maximum Input Current | 15A |
| Input Connector(s) | 1 x NEMA 5-15P |
| Cord Length | 15 ft |
| Output Voltage | 120V |
| Output Frequency | 50/60Hz |
| Output Connector(s) | 13 x NEMA 5-15R |
| Overload Protection | 15A |
| Operating Elevation | 0 - 3000 m |
| Storage Temperature | 5 to 122 degrees Fahrenheit (-15 to 50 degrees Celsius) |
| Storage Relative Humidity | 5 - 95% non-condensing |
| Features | 120V 15A Metered rackmount AC power distribution unit with 15 amp capacity and 13 AC receptacles Front panel digital current montoring display shows power consumption of connected equipment Versital all-metal rackmount cabinet with detachable mounting flanges allows wall-mount, under-counter, and 19-inch rackmount mounting in both 1U and zero U formats Unfiltered electrical pass-through reliably distributes alternate waveform AC power from UPS or generator to supported equipment 13 x NEMA 5-15R output receptacles accept common NEMA5-15P equipment plugs 15 Feet AC power cord with NEMA |
| Dimensions | 1.75" x 17.50" x 4.50" |
| Weight | 4.50 lbs. |
| Shipping weight | 2.34 kg |
| Package size | 523 × 239 × 58 mm |
Questions about this item
Should I pick this 13-outlet PDU or a version with fewer receptacles?
Choose the 13-outlet PDUMH15 when you need to power up to 13 devices from a single 15 A 120 V circuit; fewer outlets only make sense if you have a smaller device count and want to save rack space.
What does the 15 A rating mean once the unit is installed in my rack?
The front-panel LED meter shows real-time aggregate draw so you can keep total load at or below 15 A and avoid tripping the built-in 15 A overload breaker.
How does the NEMA 5-15P input and 15 ft cord limit where I can place the PDU?
The 5-15P plug requires a standard 120 V 15 A wall receptacle, and the 15 ft / 4.5 m cord restricts the PDU to within that distance from the outlet.