Tripp Lite
Tripp Lite PDU3EVSR1G60 12.6kW 200-240V 3-Phase 36 Outlets 60A 70in 0U PDU
A managed three-phase PDU distributes up to 12.6 kW across 36 switched IEC outlets with remote monitoring and per-outlet control
- TypePower Distribution Units
- 36 individually switched outlets enable remote power cycling per device
- 6 kW three-phase capacity supports high-density rack deployments
- 60 A IEC 309 3P+E input delivers 200–240 V power to all banks
- IsoBreaker technology isolates overloads to preserve critical uptime
- 70 in 0U form factor with LCD and Gigabit management fits standard racks
Data-center power management
This 0U vertical PDU is built for data centres, network service providers and large enterprises that need remote control over rack-level power distribution. A built-in network interface enables outlet-level switching, monitoring and rebooting without on-site visits, helping to reduce maintenance overhead.
36 individually switched outlets
The unit provides thirty C13 and six C19 outlets arranged in three load banks, each rated for 200-240 V three-phase input at 60 A. Every outlet has a status LED and can be monitored independently to maintain load balance across the 12.6 kW capacity.
IsoBreaker overload protection
IsoBreaker technology isolates overloads to the affected circuit, preserving power to critical equipment during fault events. The 70-inch aluminium chassis mounts in a standard rack with a 10-foot IEC-309 3P+E input cord and an LCD for local status checks.
Highlights
- 36 individually switched outlets enable remote power cycling per device
- 6 kW three-phase capacity supports high-density rack deployments
- 60 A IEC 309 3P+E input delivers 200–240 V power to all banks
- IsoBreaker technology isolates overloads to preserve critical uptime
- 70 in 0U form factor with LCD and Gigabit management fits standard racks
Specifications
| Type | Power Distribution Units |
|---|---|
| Shipping weight | 26.31 kg |
| Package size | 1918 × 248 × 152 mm |
Questions about this item
What does the 12.6 kW rating mean for actual power delivery to connected servers?
The unit can supply up to 12.6 kW across its 36 outlets when fed from a 200-240 V three-phase 60 A source, with each outlet providing 200-240 V to attached equipment.
How does the IEC 309 60 A 3P+E input connector limit the installation?
The PDU requires a matching IEC 309 60 A three-phase plus earth supply; the 10 ft cord connects directly to that inlet, so site wiring must provide the same connector and rating.
What clearance does the 70 in 0U vertical chassis need inside a rack?
The enclosure is 70 inches (1.8 m) tall and mounts in 0U vertical orientation, so the rack must offer at least 70 inches of uninterrupted vertical space along the side rails.