Tripp Lite
Tripp Lite 9PX5KTF5G2 5000VA 5000W Online UPS 18x5-20R 2xL6-20R 1xL6-30R 6U Rack/Tower
Online double-conversion UPS delivers 5000VA 5000W unity power factor with 18 NEMA 5-20R, two L6-20R, one L6-30R and hardwired output plus included NETWORK-M3 Gigabit network card for remote
- VA Rating5000 VA
- Watts5000 W
- Output Voltage240 V AC 230 V AC 220 V AC 208 V AC 200 V AC 100 V AC 110 V
- Output Frequency50 Hz 60 Hz
- Outlets18 x NEMA 5-20R 2 x NEMA L6-20R 1 x NEMA L6-30R 1 x Hardwire
- Outlet TypeNEMA 5-20R NEMA L6-20R NEMA L6-30R Hardwired
- Unity power factor delivers full 5000 W output for dense loads
- Online double-conversion topology protects against blackouts, brownouts, surges and line noise
- Hot-swappable VRLA batteries with ABM+ predictive analytics prevent unexpected downtime
- Included NETWORK-M3 Gigabit card enables full remote monitoring and control
- 21 outlets (18×5-20R, 2×L6-20R, 1×L6-30R) plus hardwired output for flexible distribution
Triple-conversion topology for critical loads
This online double-conversion UPS delivers 5000 VA and 5000 W with unity power factor, supporting servers, PoE switches and networking gear. It accepts 200 to 240 V AC input and provides selectable output voltages from 100 to 240 V AC at 50 or 60 Hz. The included NETWORK-M3 Gigabit card enables full remote management.
6U rack or tower chassis with hot-swappable
The unit measures 17.3 inches wide, 10.2 inches high and 27 inches deep, weighing 203 lbs. Eighteen NEMA 5-20R outlets, two L6-20R, one L6-30R and one hardwired output connect diverse equipment. Input uses a hardwired connection or NEMA L6-30P. Lead-acid VRLA batteries are hot-swappable and recharge in three hours.
Replaces smaller single-phase UPS units
At full load the battery runs for 3.50 minutes and at half load for 9.40 minutes, giving time for orderly shutdown. ABM+ predictive analytics flag replacement before unexpected failure. The step-down transformer and rack-mount hardware suit 6U cabinets. Buyers needing longer runtime or three-phase input must look elsewhere.
Highlights
- Unity power factor delivers full 5000 W output for dense loads
- Online double-conversion topology protects against blackouts, brownouts, surges and line noise
- Hot-swappable VRLA batteries with ABM+ predictive analytics prevent unexpected downtime
- Included NETWORK-M3 Gigabit card enables full remote monitoring and control
- 21 outlets (18×5-20R, 2×L6-20R, 1×L6-30R) plus hardwired output for flexible distribution
Specifications
| Brand | EATON |
|---|---|
| Series | 9PX G2 |
| Model | 9PX5KTF5G2 |
| Part Number | 9PX5KTF5G2 |
| VA Rating | 5000 VA |
| Watts | 5000 W |
| Output Voltage | 240 V AC 230 V AC 220 V AC 208 V AC 200 V AC 100 V AC 110 V AC 120 V AC |
| Output Frequency | 50 Hz 60 Hz |
| Outlets | 18 x NEMA 5-20R 2 x NEMA L6-20R 1 x NEMA L6-30R 1 x Hardwired |
| Outlet Type | NEMA 5-20R NEMA L6-20R NEMA L6-30R Hardwired |
| Battery Type | Lead Acid Battery |
| Battery Run Time | Backup/Run Time (Full Load): 3.50 Minute Backup/Run Time (Half Load): 9.40 Minute |
| Battery Recharge Time | 3 Hour |
| Battery Replaceable | Hot Swappable: Yes Replaceable Battery: Yes |
| Package Contents | 9PX G2 9PX5KTF5G2 5000VA Rack/tower UPS 9PXTFMR5G2 120V Step-down Transformer NETWORK-M3 Gigabit Network Card USB Cable RS-232 Cable Cable Gland for Hardwire Connection Rack-mounting Hardware Tower Support Stands Quick Start Guide |
| Shipping weight | 122.47 kg |
| Package size | 991 × 660 × 635 mm |
Questions about this item
What output voltages does the 5000 VA online UPS support for connected equipment?
The unit delivers selectable output at 100 V, 110 V, 120 V, 200 V, 208 V, 220 V, 230 V and 240 V AC at 50 Hz or 60 Hz.
What rack depth and clearance are required to mount the 6U chassis?
The chassis is 27 inches deep, 17.3 inches wide and 10.2 inches high; allow additional rear clearance for the hard-wire gland and cable bend radius.
How do you install the NETWORK-M3 Gigabit card, and what step is often missed?
Insert the card into the dedicated slot on the rear panel, secure the thumbscrews, then connect the Ethernet cable before powering on the UPS so the card initialises correctly.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.