Tough Guy
Tough Guy 2VE80 Fire-Rated Access Door 24x24 in measurement tool
Fire-rated steel access door with upward swing and insulated flush-mount design for ceiling installations
- TypeBuilding Materials
- Fire-rated protection for ceilings
- insulated steel door limits heat transfer
- hex-head slam latch secures from outside
- self-latching ring allows quick interior exit
- piano hinge ensures smooth, reliable swing
Fire-Rated Ceiling Access Door
The Tough Guy 2VE80 is a 24 by 24 inch insulated steel access door designed for ceiling installations only. It carries a fire rating tested to ASTM E119 2012 and CAN/ULC S101 2007 standards. The unit ships new with a powder-coated finish and piano hinge.
Upgrading from Non-Rated Panels
This door replaces standard unrated ceiling panels where building codes require a tested fire barrier. The jump is worth it when a project specification calls for the listed ASTM or ULC standards. It does not serve wall openings or floor hatches.
Flush Mount Build Integration
The frame requires a rough opening of 24 3/8 by 24 3/8 inches and uses eight quarter-inch mounting holes. A hex-head slam latch operates from the outside while a self-latching ring handle works from inside. The upward swing direction and ceiling-only approval constrain layout choices.
Highlights
- Fire-rated protection for ceilings
- insulated steel door limits heat transfer
- hex-head slam latch secures from outside
- self-latching ring allows quick interior exit
- piano hinge ensures smooth, reliable swing
Specifications
| Brand | TOUGH GUY |
|---|---|
| Type | Building Materials |
Questions about this item
What rough-opening size does the 24 in by 24 in door require?
The rough opening must be 24 3/8 in high by 24 3/8 in wide to fit the frame.
Which way does the piano-hinge panel swing, and what latch step is often missed?
The panel swings upward; the self-latching ring on the inside must engage fully or the door will not meet its fire rating.
When should the powder-coated steel finish and hex-head slam latch be inspected?
Inspect the finish and latch operation after any fire event or at least once a year to maintain the ASTM E119 and CAN/ULC S101 rating.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
WUQ 2-in-1 DC Power Supply & Multimeter 60V 10A 300W 2.8" LCD ATM6301
- Test Equipment
WUQ M-Type Outside Micrometer Set 0-3 inch .0001 Carbide 3 Pc EG00-0903
- Tool and Appliance…