TORK nsi
TORK nsi 2000-2 Photocontrol Dimmer Switch 4620 W 208-277 V
Photocontrol switch for dusk-to-dawn lighting control, handling 4620 W at 208-277 V AC with 1.0 to 5.0 foot-candle activation
- TypeIndustrial Electrical Controls & Automation
- Color MappingGray
- Automatic dusk-to-dawn lighting with SPST contact
- Handles up to 4,620 W across 208-277 V AC
- Raintight polycarbonate housing rated -40 to 140 °F
- Adjustable sensitivity from 1.0 to 5.0 foot-candles on
- UL 773A listed with gasket and lock nut included
Industrial Photocontrol Switch
The NSI TORK 2000-2 is a raintight photocontrol switch rated for 4620 W at 208 to 277 V AC. It mounts through a 1/2 in conduit opening and uses an SPST contact form. The polycarbonate housing includes a gasket and lock nut for outdoor installation.
Suits Dusk-to-Dawn Lighting Loads
Designed for compact fluorescent, HID, inductive and LED fixtures up to 4620 W or 16.7 A incandescent and 10 A ballast. Not for circuits that exceed the 277 V limit, for loads above the stated wattage or amperage, or for applications requiring adjustable timing beyond the fixed dusk-to-dawn operation.
Verify Voltage and Conduit Compatibility
Confirm the supply voltage falls within the 208 to 277 V AC range. Ensure the mounting location accepts a 1/2 in conduit entry and that ambient temperatures stay between -40 and 140 degrees F. Check that the connected load type and current draw remain within the published maximums.
Highlights
- Automatic dusk-to-dawn lighting with SPST contact
- Handles up to 4,620 W across 208-277 V AC
- Raintight polycarbonate housing rated -40 to 140 °F
- Adjustable sensitivity from 1.0 to 5.0 foot-candles on
- UL 773A listed with gasket and lock nut included
Specifications
| Type | Industrial Electrical Controls & Automation |
|---|---|
| Brand | NSI TORK |
| Color Mapping | Gray |
Questions about this item
What voltage supply do I need for the 208-277 V photocontrol?
The unit operates on 208 to 277 V AC, so your circuit must provide voltage within that range.
Will the 10 A ballast rating handle my existing HID fixtures?
The switch supports up to 10 A for ballast loads; verify each fixture's amp draw stays at or below that limit.
How can I confirm the dusk-to-dawn cycle is active after wiring?
Cover the sensor to simulate darkness; the load should turn on at 1.0 to 5.0 foot-candles and off again at 3 to 15 foot-candles.