Telemecanique Sensors
Telemecanique Sensors XY2CE3A010H7 Emergency Cable Pull Switch 1NO/1NC 165 ft span
Emergency cable pull switch with 1NO/1NC contacts covers a 165 ft span and resets by push button
- 165 ft cable span covers long conveyor runs
- 1NO/1NC contacts give both run and stop signals
- 3 A at 240 V AC rating suits industrial control circuits
- Zamak housing with NEMA 1, 12, 4 resists dust and water
- Push-button reset restores operation without tools
Emergency Cable Pull Switch, 165 ft Span
The Telemecanique Sensors XY2CE3A010H7 is a safety-rated emergency stop device designed for conveyor lines and machinery corridors up to 165 ft in length. It provides a single-cable pull actuation with a push-button reset, suited for industrial environments requiring accessible emergency shutdown points along extended runs.
1NO/1NC Contact Form with NEMA 1, 12, 4 Enclosure
The switch combines one normally open and one normally closed contact, allowing simultaneous signal and safety-circuit interruption. Its Zamak housing carries NEMA 1, 12, and 4 ratings for indoor protection against dust, dirt, and water ingress, while the 1/2 in NPT wiring entry simplifies conduit installation on the right-hand side.
AC 3 A at 240 V and DC 0.27 A at 250 V Thermal 10 A
The contacts are rated for 3 A at 240 V AC and 0.27 A at 250 V DC, with a thermal current capacity of 10 A. This suits standard safety-relay and PLC input circuits, but the switch is not intended for direct high-power load switching or applications requiring momentary-contact operation beyond the specified reset function.
Highlights
- 165 ft cable span covers long conveyor runs
- 1NO/1NC contacts give both run and stop signals
- 3 A at 240 V AC rating suits industrial control circuits
- Zamak housing with NEMA 1, 12, 4 resists dust and water
- Push-button reset restores operation without tools
Specifications
| Brand | TELEMECANIQUE SENSORS |
|---|
Questions about this item
How often should the Zamak housing and internal contacts be inspected or replaced on the XY2CE3A010H7?
The Zamak case and 1NO/1NC contacts have no published service interval; inspect after any activation and during routine safety audits to confirm the push-button reset latches cleanly and the 10 A thermal rating has not been exceeded.
What limits continuous operation of the XY2CE3A010H7 during a prolonged emergency stop?
The 10 A thermal amperage rating and 3 A @ 240 V AC contact rating are the first limits reached; sustained current above 10 A will cause thermal trip, while the 0.27 A @ 250 V DC rating caps DC loads.
How much heat and noise does the XY2CE3A010H7 generate when the cable is tensioned all day?
The switch is a passive mechanical device with no indicator lamp or powered coil, so it produces no audible noise and negligible heat; only the 1/2 in NPT wiring entry and cable tension remain under load.