Telemecanique Sensors
Telemecanique Sensors XY2CE2A250H7 Emergency Cable Pull Switch
Emergency cable pull switch with maintained function, 1NO/1NC contacts, 3 A at 240 V AC rating, 165 ft maximum cable span, and Zamak housing
- Maintained switch function keeps circuit state after activation
- 1NO/1NC contact form provides both normally open and closed circuits
- Zamak case material resists corrosion in industrial environments
- 165 ft maximum cable span covers long conveyor sections
- NEMA 1, 12, 4 ratings protect against dust and water ingress
Emergency Cable Pull Switch 165 ft Span
The Telemecanique Sensors XY2CE2A250H7 is a maintained-function emergency stop device that covers cable runs up to 165 ft. It provides one normally-open and one normally-closed contact rated at 3 A @ 240 V AC and 0.27 A @ 250 V DC, with a thermal current of 10 A. A booted push-button resets the switch after actuation.
Suited for single-cable safety runs on conveyors
This unit suits installations needing a left-hand cable entry and NEMA 1, 12 and 4 environmental protection. It is not for applications requiring dual-cable switching, right-side cable entry or a built-in status indicator. Buyers needing a momentary switch function or a different mounting style should look at other models.
Maintained switch with 1NO/1NC contacts
The defining specification is the maintained switch function combined with a 1NO/1NC contact form, which determines how the device latches and how it integrates into safety circuits.
Highlights
- Maintained switch function keeps circuit state after activation
- 1NO/1NC contact form provides both normally open and closed circuits
- Zamak case material resists corrosion in industrial environments
- 165 ft maximum cable span covers long conveyor sections
- NEMA 1, 12, 4 ratings protect against dust and water ingress
Specifications
| Brand | TELEMECANIQUE SENSORS |
|---|
Questions about this item
How can I verify the switch is operating correctly after installation?
After setup, pull the emergency cable to confirm the maintained contacts trip and the booted push-button reset returns the switch to its normal state.
What components are included and what must I supply separately?
The switch body with 1NO/1NC contacts, booted push-button reset, and left-side cable connection are included; you must provide the pull cable and mounting hardware.
Which NEMA rating version should I select for indoor or wet environments?
This single model carries NEMA 1, 12, and 4 ratings, so it suits general indoor, dust-tight, and wash-down locations without needing a different version.
Also in this aisle