Telemecanique Sensors XCKM110H7 Limit Switch Plunger 1NC/1NO 10A 240V AC
A miniature limit switch with a 0.98 in plunger, 1NC/1NO contacts rated 10 A at 240 V AC/DC, and NEMA 1, 2, 4, 12, 13 protection
- 1NC/1NO contacts give flexible control wiring
- 10 A at 240 V AC or DC handles heavy loads
- Miniature body fits tight machine spaces
- NEMA 1, 2, 4, 12, 13 ratings suit harsh environments
- 98 in plunger stroke ensures precise actuation
Limit Switch Plunger 10A 240V
This Telemecanique Sensors XCKM110H7 is a miniature limit switch with a top-mounted plunger actuator. It provides one normally closed and one normally open contact rated for 10A at 240V AC or DC. The switch suits machinery position sensing and safety interlock circuits in industrial environments.
NEMA 1 2 4 12 13 Enclosure
The body measures 2.48 in high, 2.52 in wide and 1.18 in deep with a 0.98 in actuator length. It carries NEMA type 1, 2, 4, 12 and 13 ratings for protection against dust, water and oil ingress. Surface mounting allows direct installation on machine frames or control panels.
Upgrade From Basic Snap Switches
This switch replaces unsealed snap-action switches where environmental protection is required. The jump is worth it when the application demands NEMA 4 or 13 sealing against coolant splash or oil. It is not for buyers who need a boot-sealed actuator or a different actuator style such as roller or lever.
Highlights
- 1NC/1NO contacts give flexible control wiring
- 10 A at 240 V AC or DC handles heavy loads
- Miniature body fits tight machine spaces
- NEMA 1, 2, 4, 12, 13 ratings suit harsh environments
- 98 in plunger stroke ensures precise actuation
Specifications
| Brand | TELEMECANIQUE SENSORS |
|---|
Questions about this item
How do I mount the XCKM110H7 limit switch and what step is often missed?
Mount it on a flat surface using the two through-holes in the 2.52 in wide by 1.18 in deep miniature body; the step often missed is torquing the M4 screws to the manufacturer's specification so the 0.98 in plunger stays aligned and the NEMA 1, 2, 4, 12, 13 seals remain effective.
What part of the XCKM110H7 will need replacement first and how can I tell?
The plunger actuator and its internal snap-action contacts wear first; replace the switch when the 1NC/1NO contacts no longer make or break cleanly at 10 A 240 V AC/DC or when the 0.98 in plunger travel feels gritty or sticks.
What is the first limit reached when the XCKM110H7 runs continuously at full load?
The 10 A at 240 V AC/DC contact rating is the first limit; sustained operation at that current will cause contact temperature to rise until the snap-action mechanism can no longer guarantee reliable 1NC/1NO switching.