Telemecanique Sensors
Telemecanique Sensors XCKL110H7 limit switch plunger 1NC/1NO 10A 240V
A miniature limit switch with a top-mounted plunger rated 10 A at 240 V and 1NC/1NO contacts
- Reliable switching with 1NC/1NO contact form
- Handles up to 10A at 240V AC or DC
- Compact miniature body fits tight spaces at 2.83 in high
- NEMA 1, 2, 3, 4, 12 ratings suit harsh environments
- Top-mounted plunger with 0.98 in actuator for precise actuation
Industrial limit switch for machine control
The Telemecanique Sensors XCKL110H7 is a miniature limit switch with a top-mounted plunger actuator. It provides one normally closed and one normally open contact rated at 10A for both 240V AC and 240V DC circuits. The NEMA 1, 2, 3, 4 and 12 rated enclosure suits industrial environments requiring protection against dust and water ingress.
10A contact rating handles standard control circuits
The switch comfortably manages typical relay coils, solenoid valves and indicator lamps found in automation panels. Its 240V AC and DC rating covers common control voltage levels without derating. The single-pole double-throw arrangement limits use to one circuit path; applications needing multiple isolated circuits require additional switches.
Surface mounting with compact dimensions
The body measures 2.83 in high, 2.04 in wide and 1.18 in deep with a 0.98 in actuator length, fitting tight machine frames. Surface mounting uses two through-holes for secure attachment to panels or brackets. The unsealed plunger actuator requires a clean operating environment to prevent debris from affecting travel or contact reliability.
Highlights
- Reliable switching with 1NC/1NO contact form
- Handles up to 10A at 240V AC or DC
- Compact miniature body fits tight spaces at 2.83 in high
- NEMA 1, 2, 3, 4, 12 ratings suit harsh environments
- Top-mounted plunger with 0.98 in actuator for precise actuation
Specifications
| Brand | TELEMECANIQUE SENSORS |
|---|
Questions about this item
Will the 0.98 in plunger actuator align with my existing 2.04 in wide mounting surface?
The miniature body measures 2.04 in wide by 1.18 in deep, and the top-mounted plunger extends 0.98 in, so you can verify hole spacing against those dimensions before installation.
How can I confirm the 1NC/1NO contacts are switching correctly at 10A 240V after wiring?
Apply a known load up to 10 amps at 240 volts AC or DC and use a multimeter to verify the normally-open contact closes and the normally-closed contact opens when the plunger is fully depressed.
Does the switch include mounting hardware or only the NEMA 1, 2, 3, 4, 12 rated body?
The supplied unit is the surface-mount limit switch body with integrated plunger actuator; mounting screws, wiring connectors and any external actuators are not included and must be sourced separately.