TAURKENAM
TAURKENAM NEMA 5-20P to 5-20R/5-15R extension cord 12 AWG 20A 125V 2500W 25FT
A 25-foot extension cord with a NEMA 5-20P plug and a 5-20R/5-15R receptacle, using 12 AWG copper wire rated for 20 A, 125 V and 2500 W
- Handles 20 A loads with 12 AWG copper conductors
- 25 ft reach extends power to distant equipment
- UL-approved STW jacket rated for heavy-duty use
- 5-20R T-blade outlet also accepts 5-15 plugs
- 125 V 2500 W capacity suits high-draw devices
NEMA 5-20P to 5-20R/5-15R extension cord
This 25-foot extension cord connects a NEMA 5-20P male plug to a female receptacle that accepts both 5-20R T-blade and standard 5-15R plugs. It uses 12 AWG copper conductors rated for 20 amps at 125 volts, delivering up to 2500 watts. The STW jacketed cable is UL approved for heavy-duty use.
Indoor equipment needing a longer 20-amp reach
Suitable for workshops, garages or server racks where a 20-amp outlet must be extended to equipment with either a 5-20P or 5-15P plug. Not for outdoor permanent installation, wet locations or circuits exceeding the 20-amp, 2500-watt rating. Buyers needing a different length should choose another option from the 2, 6, 10, 16, 50 or 100-foot range.
12 AWG copper wire rated 20 amps at 125 volts
The 12 AWG 100-percent copper conductor determines the safe continuous load of 20 amps and 2500 watts at 125 volts. UL-listed STW construction confirms the cable meets the required safety standard for this ampacity. Verify your circuit breaker and equipment draw match these limits before use.
Highlights
- Handles 20 A loads with 12 AWG copper conductors
- 25 ft reach extends power to distant equipment
- UL-approved STW jacket rated for heavy-duty use
- 5-20R T-blade outlet also accepts 5-15 plugs
- 125 V 2500 W capacity suits high-draw devices
Specifications
No published specifications for this item yet.
Questions about this item
How do I connect the NEMA 5-20P plug to a 5-15R outlet using this cord?
The female end accepts both 5-20R and 5-15R plugs, so you simply insert the 5-15R plug into the receptacle; the T-blade slot accommodates the neutral blade.
Will the 12 AWG copper conductors need replacement after heavy use?
The 100% copper wire inside the STW jacket is rated for continuous 20 A loading and does not require scheduled replacement under normal conditions.
At what load does the 25 ft length hit its thermal limit first?
The UL-approved 12 AWG STW cable supports a maximum of 20 A at 125 V (2500 W); sustained loads at that rating reach the ampacity limit before voltage drop becomes critical.