SYLVANIA
SYLVANIA HPL 750W 120V HPL750120X Long Life Halogen standard bulb
750-watt halogen lamp with G 9.5 bi-pin base, 16,400 lumens at 3,065 K and 2,000-hour life
- TypeHalogen Bulbs
- Lumen Range16400
- Wattage750
- Color Temperature3065K
- Life Time Hours2000
- Color Rendering Index100
- High output of 16400 lumens for bright stage lighting
- 750 W halogen lamp runs on standard 120 V supply
- Long 2000-hour rated life reduces replacement frequency
- Perfect CRI 100 renders colours accurately on set
- G 9.5 bi-pin base fits compatible fixtures directly
High-Output Halogen Lamp for Stage and Studio
The OSRAM HPL 750W 120V lamp delivers 16400 lumens at a 3065K colour temperature with a CRI of 100. It uses a G 9.5 bi-pin base and a clear T6 envelope. Designed for professional fixtures requiring intense, accurate white light.
Thermal Characteristics and Power Profile
The 750 watt halogen filament operates at 120 volts and generates significant heat during use. Fixtures must provide adequate ventilation to manage thermal load. Rated life is 2000 hours under normal cycling conditions.
Integration Requirements for Fixtures
This lamp requires a socket compatible with the G 9.5 bi-pin base and a 120V supply circuit rated for 750W. The clear T6 form factor fits standard ellipsoidal and follow-spot housings. It frees designers from lower-output alternatives when maximum punch is essential.
Highlights
- High output of 16400 lumens for bright stage lighting
- 750 W halogen lamp runs on standard 120 V supply
- Long 2000-hour rated life reduces replacement frequency
- Perfect CRI 100 renders colours accurately on set
- G 9.5 bi-pin base fits compatible fixtures directly
Specifications
| Brand | OSRAM |
|---|---|
| Type | Halogen Bulbs |
| Lumen Range | 16400 |
| Wattage | 750 |
| Color Temperature | 3065K |
| Life Time Hours | 2000 |
| Color Rendering Index | 100 |
Questions about this item
How do I install the G 9.5 bi-pin base correctly and what is the common mistake?
Align the two pins with the socket slots and push straight in until the base seats fully; the frequent error is twisting the lamp like a screw base, which bends the pins and prevents contact.
What maintenance or replacement will the 2000-hour halogen lamp need later?
Plan to replace the bulb after roughly 2000 hours of operation; halogen capsules cannot be cleaned or re-gassed, so a new 750 W 120 V unit is the only service action.
At 750 W continuous draw, what limit appears first during sustained use?
The fixture’s 750 W / 120 V rating and wiring capacity are reached immediately, so the thermal and electrical limit of the socket and supply circuit is the first constraint.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.