SQUARE D
SQUARE D 9001BW100YU Pendant Push Button Station 2NO 2 Speed Yellow
A yellow thermoplastic pendant station with two momentary push buttons, 2NO contacts rated 5A at 600V, and NEMA 1, 3, 3R, 4, 4X enclosure
- TypeIndustrial Electrical Controls & Automation
- Two-speed control with momentary push buttons
- 2NO contacts rated 5A at 600V AC/DC
- Thermoplastic enclosure rated NEMA 1, 3, 3R, 4, 4X
- Mechanical interlock prevents simultaneous activation
- Yellow hand-grip station with 1/2 in. NPT hub
Two-speed pendant control station
The SQUARE D 9001BW100YU is a yellow thermoplastic pendant station designed for industrial control circuits. It provides two momentary push-button operators with a mechanical interlock to prevent simultaneous activation. Rated for 5 A at 600 V AC/DC, it suits machinery requiring simple two-speed or forward-reverse control.
NEMA-rated enclosure and interlock
The enclosure carries NEMA 1, 3, 3R, 4 and 4X ratings for indoor and outdoor wash-down environments. A mechanical interlock between the two operators ensures only one circuit can be energised at a time. CE, CSA and UL listings confirm compliance with North American and European safety standards for industrial control equipment.
Hand-grip mounting with half-inch hub
A built-in hand grip allows direct handheld operation while the 1/2 in.-14 NPT hub provides a standard conduit entry for cable connection. The compact 4.69 in height, 2.19 in width and 2.94 in depth enclosure fits comfortably in the hand. Thermoplastic construction resists corrosion and impact in harsh industrial settings.
Highlights
- Two-speed control with momentary push buttons
- 2NO contacts rated 5A at 600V AC/DC
- Thermoplastic enclosure rated NEMA 1, 3, 3R, 4, 4X
- Mechanical interlock prevents simultaneous activation
- Yellow hand-grip station with 1/2 in. NPT hub
Specifications
| Brand | SQUARE D |
|---|---|
| Type | Industrial Electrical Controls & Automation |
Questions about this item
Will the 1/2 in. -14 NPT hub threads need resealing after years of vibration?
The 1/2 in. -14 NPT hub uses tapered pipe threads; apply fresh pipe sealant or PTFE tape whenever the station is removed for inspection to maintain the NEMA 4X seal.
Which rating — 5 A at 600 V or the B600/P600 designation — limits continuous duty first?
Both describe the same contact capability; the 5 A at 600 V AC/DC rating is the hard limit, so sustained loads above 5 A will overheat the contacts before any other factor.
Does the thermoplastic enclosure stay cool enough for all-day hand-held use?
The contacts are rated 5 A at 600 V; at or below that load the enclosure remains near ambient temperature, making it comfortable for continuous hand-held operation.