SOUTHWIRE COMPANY
SOUTHWIRE COMPANY 27022301 TFFN 18 AWG White 500 ft conduit
18 AWG stranded TFFN fixture wire with PVC insulation and nylon jacket, 600 V rating, on a 500 ft spool
- Color/FinishWhite
- TypeWire & Cable Staples
- Length6.500
- TFFN fixture wire rated for 600V AC circuits
- 18 AWG stranded conductor with 16 strands for flexibility
- White nylon jacket over PVC insulation resists abrasion
- 500 ft spool supplies long continuous pulls
- Nominal 0.09 in diameter fits tight conduit runs
Fixture wire for conduit runs
Southwire 27022301 is a single-conductor TFFN fixture wire built for installation in conduit systems. The 18 AWG stranded copper conductor carries a 600 V AC rating and is insulated with PVC under a white nylon jacket measuring 0.09 in nominal outside diameter. Supplied on a 500 ft spool, it suits commercial and residential lighting circuits pulled through raceway.
Replaces solid hook-up wire in raceway
Stranded 16-strand construction makes this wire far easier to pull through bends and long conduit runs than solid alternatives. The nylon jacket resists abrasion during installation, reducing insulation damage that would require re-pulling. The upgrade is worth it whenever conduit fill, frequent bends or long distances make solid wire difficult to handle.
Limited to protected conduit environments
TFFN insulation is not rated for direct burial, exposed outdoor use or installation without a raceway. The 600 V rating applies only when the wire remains inside listed conduit or tubing. Installers must follow applicable code for conductor fill, temperature derating and overcurrent protection; the wire itself provides no additional circuit protection.
Highlights
- TFFN fixture wire rated for 600V AC circuits
- 18 AWG stranded conductor with 16 strands for flexibility
- White nylon jacket over PVC insulation resists abrasion
- 500 ft spool supplies long continuous pulls
- Nominal 0.09 in diameter fits tight conduit runs
Specifications
| Brand | SOUTHWIRE |
|---|---|
| Color/Finish | White |
| Type | Wire & Cable Staples |
| Length | 6.500 |
Questions about this item
What conduit size fits the 0.09 in outside diameter of this 18 AWG TFFN wire?
Choose conduit with an inside diameter large enough for the 0.09 in wire OD plus NEC fill limits; 1/2 in EMT is commonly used for single 18 AWG runs.
How do you pull 500 ft of this stranded TFFN through conduit without damaging the nylon jacket?
Use wire-pulling lubricant, feed from the spool straight into the conduit, and avoid sharp bends that exceed the minimum bend radius for 18 AWG stranded conductors.
When should the white nylon jacket on this 600V TFFN wire be inspected or replaced?
Inspect the jacket for cuts, abrasion, or discoloration after any pulling job and before energising; replace any length where the nylon is breached or the PVC insulation is exposed.