Simplex
Simplex 4098-XAD-210 security
Dual-zone air sampling smoke detector provides early fire detection across two separate monitoring areas
- TypeSmoke Detector
- Dual-zone air sampling covers two separate areas
- Early smoke detection through active air sampling technology
- Simplex 4098-XAD-210 model ensures reliable fire safety
- New condition guarantees full operational performance
- Designed for home safety and security applications
Dual-zone detection approach
The Simplex 4098-XAD-210 is a dual zone air sampling smoke detector designed for early fire identification. It actively draws air samples through a pipe network to detect smoke particles at the earliest stages of combustion. This method provides coverage for environments where standard spot detectors may be unsuitable or ineffective. The unit is supplied new and ready for integration into a compatible fire alarm system.
Suited for high-airflow or high-ceiling spaces
This detector suits facilities such as data centres, warehouses or cleanrooms where stratification or ventilation delays smoke reaching ceiling-mounted units. It also serves areas requiring very early warning to protect high-value assets or critical operations. Buyers needing a simple spot-type detector for standard residential or small commercial rooms should look at other device types that mount directly on the ceiling.
Two independent sampling zones
The defining specification is the dual zone architecture identified by the 4098 model designation. This allows the detector to monitor two separate pipe networks or areas from a single unit, providing distinct alarm signals for each zone. This capability reduces the total number of detectors required for partitioned spaces while maintaining area-specific detection data.
Highlights
- Dual-zone air sampling covers two separate areas
- Early smoke detection through active air sampling technology
- Simplex 4098-XAD-210 model ensures reliable fire safety
- New condition guarantees full operational performance
- Designed for home safety and security applications
Specifications
| Type | Smoke Detector |
|---|
Questions about this item
How often does the air-sampling pipe network on the 4098-XAD-210 need cleaning?
The pipe network should be inspected annually and cleaned whenever dust buildup restricts airflow to the detector chamber.
What limits continuous operation of the 4098-XAD-210 dual-zone detector?
The detector will signal a fault if airflow in either sampling zone drops below the calibrated threshold.
How much heat does the 4098-XAD-210 generate when running all day?
The unit produces only minimal heat during continuous monitoring, well within standard enclosure limits.