Silverstone
Silverstone PS-GM1300C-PF 1300W+1300W 2U CRPS server power supply
Dual 1300W redundant 2U CRPS supply with Cybenetics Platinum efficiency and 2394W/L density
- Cybenetics Platinum certification for high efficiency
- Redundant 2U CRPS form factor ensures uptime
- 1300W+1300W combined output powers dense servers
- Active PFC above .9 at full load
- 100000-hour MTBF backed by 40mm DC cooling
2U CRPS Redundant Power Supply
The Silverstone PS-GM1300C-PF delivers a redundant 1300W+1300W output in a 2U CRPS form factor. It targets data-centre operators and server integrators who need continuous uptime for critical workloads. The hot-swap design allows a failed module to be replaced without powering down the chassis.
Replaces single non-redundant units
Moving from a single PSU to this redundant pair removes a single point of failure for mission-critical systems. The jump is justified when downtime costs exceed the added hardware investment. Each module shares the load, reducing individual stress and extending service life.
Fits 2U CRPS bays with active cooling
The unit slides into standard 2U CRPS bays and uses 40mm DC fans for airflow. Active PFC maintains a power factor above .9 at full load while combined 3.3V and 5V rails supply up to 200W. Cybenetics Platinum certification confirms high efficiency across the operating range.
Highlights
- Cybenetics Platinum certification for high efficiency
- Redundant 2U CRPS form factor ensures uptime
- 1300W+1300W combined output powers dense servers
- Active PFC above .9 at full load
- 100000-hour MTBF backed by 40mm DC cooling
Specifications
No published specifications for this item yet.
Questions about this item
What rack space and form factor does this 2U CRPS redundant power supply require?
It fits a standard 2U rack slot and uses the CRPS redundant form factor for hot-swap installation.
How do I install the unit and what step is often missed?
Slide the module into the 2U bay until the latch clicks, then connect the AC cord; the step often missed is fully seating the latch to engage the redundant bus.
When will the 40 mm DC fans need attention and what is the rated MTBF?
The 40 mm DC fans are rated for 100000 hours MTBF; plan inspection or replacement around that interval.
New to this? Buying PC parts with Monero — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
minisforum MF-SRP01 SSD Heatsink accessories barebone
- SSD Heatsink
Intel HNS2600BPS24R 2U barebone pc dual Xeon DDR4 2.80 TB C622
- Xeon Bronze Xeon Go…
- DDR4-2933/PC4-23466