SIGLENT TECHNOLOGIES CO.,LTD
SIGLENT TECHNOLOGIES CO.,LTD SDS1204X-E 200MHz 4 Channel 1 GSa/s 14 MB Grey electrical system tool
A 200 MHz four-channel oscilloscope with 1 GSa/s sampling and 14 MB memory depth for detailed signal analysis
- 200 MHz bandwidth captures fast signals accurately
- 1 GSa/s sample rate resolves fine waveform detail
- 14 Mpts memory depth enables long capture analysis
- 100,000 wfm/s update rate catches rare glitches quickly
- 7-inch 800×480 display shows clear waveform detail
What it is
The Siglent SDS1204X-E is a four-channel digital oscilloscope with a 200 MHz bandwidth and a 1 GSa/s sample rate. A 7-inch TFT-LCD shows waveforms at 800 by 480 resolution, and the instrument captures up to 100,000 waveforms per second in normal mode. Serial decoding for IIC, SPI, UART, CAN and LIN is included as standard.
Who it suits
Engineers debugging mixed-signal circuits benefit from the deep 14 Mpts memory that measurement and math functions can fully address. The hardware pass-fail engine performs up to 40,000 mask tests per second for production-line monitoring. Buyers who need more than four simultaneous analog channels or a higher sample rate should look at other instruments.
Capacity and headroom
The 14 Mpts record length provides ample headroom for long captures at full resolution, and the 1 Mpts FFT supports detailed frequency analysis. Voltage scales range from 500 V per division down to 10 V per division with low background noise. Optional Wi-Fi and standard web-browser control add remote flexibility for the four-channel model.
Highlights
- 200 MHz bandwidth captures fast signals accurately
- 1 GSa/s sample rate resolves fine waveform detail
- 14 Mpts memory depth enables long capture analysis
- 100,000 wfm/s update rate catches rare glitches quickly
- 7-inch 800×480 display shows clear waveform detail
Specifications
No published specifications for this item yet.
Questions about this item
What probes or cables must I already have to use the four channels on this oscilloscope?
You will need four oscilloscope probes rated for at least 200 MHz bandwidth to connect signals to the four BNC inputs.
Can I keep using my existing 100 MHz probes with this 200 MHz model?
Yes, 100 MHz probes will work but they limit the overall system bandwidth to 100 MHz on the channels where they are used.
How do I verify the 100,000 wfm/s capture rate is active in normal mode?
Check the acquisition status readout on the 800 * 480 display; it shows the real-time waveform capture rate during operation.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.



