SIEMENS 5SY41205 20 A 230/400V AC 1 Pole DIN Rail Supplementary Protector
Single-pole DIN-rail supplementary protector rated 20 A at 230/400 V AC with 10 kA interrupting capacity and screw-clamp terminals
- Engine BrandSIEMENS
- 20 A rated current protects circuits up to 20 A
- 10 kA interrupting capacity clears faults at 230/400 V AC
- Thermal-magnetic trip responds to overloads and short circuits
- DIN-rail mounting fits standard industrial panels
- Screw-clamp terminals accept 14 to 4 AWG wire
Industrial supplementary protector
The SIEMENS 5SY41205 is a single-pole IEC supplementary protector rated at 20 A for 230/400V AC circuits. It mounts on a standard DIN rail and uses a thermal-magnetic trip mechanism with Curve Type A characteristics. The toggle actuator provides clear on/off status for industrial control panels.
Capacity and headroom
The device carries a maximum AIR rating of 10kA at 230/400V AC and is also rated for 72V DC. Screw-clamp terminals accept conductors from 14 AWG up to 4 AWG, giving installers flexibility for various load sizes. It meets UL 1077 requirements for supplementary protection in industrial equipment.
Upgrade context
This protector replaces older supplementary breakers that lack the 10kA interrupting capacity or the dual AC/DC voltage rating. The jump is worth it when panel designs demand higher short-circuit withstand and a compact 0.69 in width per pole. It does not serve as a branch-circuit breaker for main distribution boards.
Highlights
- 20 A rated current protects circuits up to 20 A
- 10 kA interrupting capacity clears faults at 230/400 V AC
- Thermal-magnetic trip responds to overloads and short circuits
- DIN-rail mounting fits standard industrial panels
- Screw-clamp terminals accept 14 to 4 AWG wire
Specifications
| Engine Brand | SIEMENS |
|---|
Questions about this item
Will the 20 A 1-pole breaker coordinate with existing 10 kA rated devices on the same 230/400 V AC panel?
Yes, the 5SY41205 carries a 10 kA AIR rating at 230/400 V AC, matching the interrupting capacity of other 10 kA supplementary protectors on the same bus.
How can I verify the thermal-magnetic trip is operating correctly after wiring to the DIN rail?
Apply rated current and confirm the toggle remains closed; a controlled overload should open the toggle within the Curve A time-current band, then reset cleanly when the handle is cycled.
Does the box include screw-clamp terminals for 14 AWG to 4 AWG wire or must I order lugs separately?
The supplementary protector ships with integral screw-clamp terminals that accept 14 AWG through 4 AWG conductors; no additional lugs are required.