We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

SIEMENS

SIEMENS 5SJ41106HG40 10A 1 Pole Circuit Breaker

SKU CH-5TWA-VDAJF

A 10 A single-pole miniature circuit breaker with B-curve thermal-magnetic trip, 14 kA interrupting rating at 240 V AC, and DIN-rail screw-clamp terminals for branch-circuit protection

  • 10 A thermal magnetic trip protects branch circuits
  • 14 kA interrupting rating at 240 V AC handles high fault currents
  • DIN rail mounting fits standard industrial enclosures
  • Screw clamp terminals accept 14 to 4 AWG conductors
  • UL 489 listed for branch circuit protection

IEC 10 A Miniature Breaker

This Siemens 5SJ4 series miniature circuit breaker provides 10 A branch-circuit protection on a single pole. It carries a B-curve thermal-magnetic trip and is rated for 240 V AC and 60 V DC with a 14 kA interrupting capacity at 240 V AC. The device mounts on standard DIN rail and accepts screw-clamp terminals from 14 AWG up to 4 AWG.

Installers needing single-pole AC

Electricians and panel builders who require a compact, DIN-rail device for 10 A lighting, receptacle or control circuits will find the ratings match common industrial and commercial specs. Projects that demand multi-pole switching, higher current ratings or a different trip curve should select an alternative model.

Screw-clamp terminals simplify wiring

The screw-clamp connection accommodates a wide conductor range from 14 AWG to 4 AWG, reducing the need for special lugs or ferrules. Reverse-feed capability adds flexibility when the breaker is fed from either end. No additional accessories or software are included in the package.

Highlights

  • 10 A thermal magnetic trip protects branch circuits
  • 14 kA interrupting rating at 240 V AC handles high fault currents
  • DIN rail mounting fits standard industrial enclosures
  • Screw clamp terminals accept 14 to 4 AWG conductors
  • UL 489 listed for branch circuit protection

Specifications

BrandSIEMENS

Questions about this item

What mounting rail does the 5SJ41106HG40 need?

It mounts on a DIN rail as indicated by the DIN Rail mounting style in the specifications.

Can the 10 A breaker share a DIN rail with older 63 A frame devices?

Yes, the frame size is listed as 63A/5SJ4 so it fits the same rail system as other 63 A frame breakers.

How do I verify the 5SJ41106HG40 is working after wiring?

Apply load up to 10 A and confirm the thermal magnetic trip does not operate; a sustained overload above 10 A should cause the breaker to open the circuit.