SIEMENS 5SJ41106HG40 10A 1 Pole Circuit Breaker
A 10 A single-pole miniature circuit breaker with B-curve thermal-magnetic trip, 14 kA interrupting rating at 240 V AC, and DIN-rail screw-clamp terminals for branch-circuit protection
- 10 A thermal magnetic trip protects branch circuits
- 14 kA interrupting rating at 240 V AC handles high fault currents
- DIN rail mounting fits standard industrial enclosures
- Screw clamp terminals accept 14 to 4 AWG conductors
- UL 489 listed for branch circuit protection
IEC 10 A Miniature Breaker
This Siemens 5SJ4 series miniature circuit breaker provides 10 A branch-circuit protection on a single pole. It carries a B-curve thermal-magnetic trip and is rated for 240 V AC and 60 V DC with a 14 kA interrupting capacity at 240 V AC. The device mounts on standard DIN rail and accepts screw-clamp terminals from 14 AWG up to 4 AWG.
Installers needing single-pole AC
Electricians and panel builders who require a compact, DIN-rail device for 10 A lighting, receptacle or control circuits will find the ratings match common industrial and commercial specs. Projects that demand multi-pole switching, higher current ratings or a different trip curve should select an alternative model.
Screw-clamp terminals simplify wiring
The screw-clamp connection accommodates a wide conductor range from 14 AWG to 4 AWG, reducing the need for special lugs or ferrules. Reverse-feed capability adds flexibility when the breaker is fed from either end. No additional accessories or software are included in the package.
Highlights
- 10 A thermal magnetic trip protects branch circuits
- 14 kA interrupting rating at 240 V AC handles high fault currents
- DIN rail mounting fits standard industrial enclosures
- Screw clamp terminals accept 14 to 4 AWG conductors
- UL 489 listed for branch circuit protection
Specifications
| Brand | SIEMENS |
|---|
Questions about this item
What mounting rail does the 5SJ41106HG40 need?
It mounts on a DIN rail as indicated by the DIN Rail mounting style in the specifications.
Can the 10 A breaker share a DIN rail with older 63 A frame devices?
Yes, the frame size is listed as 63A/5SJ4 so it fits the same rail system as other 63 A frame breakers.
How do I verify the 5SJ41106HG40 is working after wiring?
Apply load up to 10 A and confirm the thermal magnetic trip does not operate; a sustained overload above 10 A should cause the breaker to open the circuit.