Shenzhen Junxiangcheng Technology Co.,
Shenzhen Junxiangcheng Technology Co., 2U 24-disk server chassis 12Gb/s SAS expander
A 2U server chassis holding 24 front 2.5" drives and 3 internal 2.5" drives with a 12Gb/s SAS expander backplane
- Form Factor2U
- 24 front 2.5" drive bays for high-density storage
- 12Gb/s SAS expander backplane with SFF-8643 interface
- 3 built-in 2.5" drive positions add internal capacity
- 4 hot-swappable 8025 fan positions with temperature control
- 7 half-height PCIe slots support vertical expansion cards
24-Drive 2U Server Chassis
This 2U chassis holds twenty-four front 2.5-inch drives and three internal 2.5-inch drives for dense storage deployments. It accepts standard motherboards up to 12 by 13 inches and fits in 650-millimetre deep racks. The expander backplane runs at 12Gb/s over Mini-SAS HD SFF-8643 links. Builders needing more than twenty-seven drive bays or a different form factor should look elsewhere.
Thermals and Power in Normal Use
Three hot-swappable 8025 ball fans occupy four 8-centimetre positions and operate under temperature control. The chassis supports standard 2U power supplies and CRPS redundant units up to 240 millimetres long. Front light-guide columns show drive activity while the anti-EMI drive trays slide smoothly. The 1.0-millimetre SGCC shell resists fingerprints.
Behaviour Under Sustained Load
Time-sharing spin-up sequences stagger drive starts to limit inrush current during heavy array rebuilds. The expander backplane includes SGPIO signalling and temperature monitoring to manage sustained throughput. Seven vertical half-height PCIe slots accommodate long-term compute or HBA cards. System LEDs report power, fan, overheat and UID status continuously.
Highlights
- 24 front 2.5" drive bays for high-density storage
- 12Gb/s SAS expander backplane with SFF-8643 interface
- 3 built-in 2.5" drive positions add internal capacity
- 4 hot-swappable 8025 fan positions with temperature control
- 7 half-height PCIe slots support vertical expansion cards
Specifications
| Form Factor | 2U |
|---|
Questions about this item
How do I install the 12Gb/s SAS expander backplane with Mini-SAS HD SFF8643 cables, and what step is often missed?
Connect each SFF8643 cable from the RAID controller to the backplane ports, then verify the SGPIO link so drive LEDs show activity.
What maintenance will the three 8025 ball fans and hot-swap drive trays need later?
Clean fan filters quarterly; fans are hot-swappable so replace any failed unit without downtime. Trays need only occasional latch inspection.
Which limit appears first under sustained load — the 240 mm PSU depth or the 650 mm chassis depth for airflow?
The 240 mm PSU depth restriction is the first constraint; ensure redundant CRPS units fit within that length for proper cooling.
New to this? Buying PC parts with Monero — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
minisforum MF-SRP01 SSD Heatsink accessories barebone
- SSD Heatsink
Intel HNS2600BPS24R 2U barebone pc dual Xeon DDR4 2.80 TB C622
- Xeon Bronze Xeon Go…
- DDR4-2933/PC4-23466