Schneider Electric
Schneider Electric NSYTRV22PE 2.5 mm² Grounding Terminal Block 12 AWG
A grounding terminal block with 2.5 mm² cross-section, screw connection and -40 to 130 °C operating range
- Engine BrandSCHNEIDER ELECTRIC
- Secure grounding with 2.5 mm² cross section
- Wide operating range from -40 to 130 °C
- Multi-standard certified for global compliance
- Tool-free clip-on mounting on DIN rail
- Compatible with Prisma and Spacial enclosures
Grounding Terminal Block 2.5 mm²
The Schneider Electric NSYTRV22PE is a single-pole grounding terminal block designed for industrial control panels. It accepts 12 AWG conductors with a 2.5 mm² nominal cross section and mounts by clip-on onto standard DIN rails. The green-yellow housing identifies the protective earth function clearly.
Operating Temperature Range -40 to 130 °C
The terminal block operates reliably from -40 to 130 °C ambient air temperature, conforming to IEC 60216-1 and VDE 0304-T21 standards. Screw terminals provide secure connections that resist vibration in demanding environments. No active cooling or power draw is required for this passive component.
Multi-Standard Certified for Enclosure Compatibility
The block carries ATEX, CSA, cURus, DNV, GL, LR, VDE, IEC-Ex and EAC certifications for global compliance. It is compatible with Spacial enclosures for Prisma G, Prisma P, Pragma, Prisma PH, Prisma Pack, Spacial, Kaedra and TeSys ranges. Sideways connection allows dense wiring in confined spaces.
Highlights
- Secure grounding with 2.5 mm² cross section
- Wide operating range from -40 to 130 °C
- Multi-standard certified for global compliance
- Tool-free clip-on mounting on DIN rail
- Compatible with Prisma and Spacial enclosures
Specifications
| Engine Brand | SCHNEIDER ELECTRIC |
|---|
Questions about this item
How do I clip the NSYTRV22PE onto a DIN rail and which screw terminal step is often missed?
Snap the block onto the rail until the clip locks, then tighten the single-level 1x1 screw terminals with a screwdriver; the step people skip is fully seating the wire before torquing the screw.
What maintenance or replacement will the grounding block need over time?
The screw terminals may loosen with thermal cycling from -40 to 130 °C; re-torque them during scheduled panel inspections and replace the block if the green-yellow housing shows cracking or discoloration.
What is the first limit reached under continuous heavy current?
The 2.5 mm² cross-section and 12 AWG rating set the ampacity ceiling; sustained loads beyond that will hit the conductor temperature limit before the -40 to 130 °C ambient range becomes a factor.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.



