Schneider Electric M9F22102 C60SP Miniature Circuit Breaker 2A 1P
A 2 A single-pole miniature circuit breaker with thermal-magnetic trip, C-curve response and 14 kA interrupting capacity at 120/240 V AC
- Reliable branch-circuit protection with thermal-magnetic trip mechanism
- High interrupting capacity rated at 14 kA for 120/240 V AC
- Compact DIN-rail mount fits panels at just 0.71 in wide
- Secure screw-clamp terminals accept 18 to 8 AWG conductors
- Certified to UL 1077 for supplementary protector applications
C60SP 2 A Miniature Circuit Breaker
The Schneider Electric M9F22102 is a single-pole supplementary protector rated at 2 A for branch circuit protection. It suits panels that require IEC and UL 1077 recognised devices on DIN rail.
Thermal Magnetic Trip and 14 kA Interrupting
A thermal magnetic mechanism provides overload and short-circuit response on AC circuits up to 240/415 V. The unit delivers a maximum AIR rating of 14 kA at 120/240 V AC and is also rated for 60 V DC operation.
DIN Rail Mount with Screw Clamp Terminals
The toggle actuator and DIN rail mounting style allow quick installation in standard enclosures. Screw clamp terminals accept conductors from 18 AWG to 8 AWG within a 3.19 in by 0.71 in by 2.83 in footprint.
Highlights
- Reliable branch-circuit protection with thermal-magnetic trip mechanism
- High interrupting capacity rated at 14 kA for 120/240 V AC
- Compact DIN-rail mount fits panels at just 0.71 in wide
- Secure screw-clamp terminals accept 18 to 8 AWG conductors
- Certified to UL 1077 for supplementary protector applications
Specifications
| Brand | SCHNEIDER ELECTRIC |
|---|
Questions about this item
How do I mount the C60SP 1-pole breaker and which wiring step is often missed?
Snap the breaker onto a DIN rail and secure the screw-clamp terminals with wire between 18 AWG and 8 AWG; the step often missed is confirming the conductor fits the clamp range before tightening.
What maintenance or replacement will the 2 A thermal-magnetic breaker need over time?
No routine maintenance is required; replace the unit if it trips repeatedly under normal load, shows discoloration at the terminals, or fails to reset cleanly after a fault.
What is the first limit reached when the 2 A breaker runs continuously at full load?
The thermal element will trip first on sustained overload, while the magnetic release responds only to short-circuit currents up to the 14 kA interrupting rating.