We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Schneider Electric

Schneider Electric M9F22102 C60SP Miniature Circuit Breaker 2A 1P

SKU CH-WFCK-1FWJD

A 2 A single-pole miniature circuit breaker with thermal-magnetic trip, C-curve response and 14 kA interrupting capacity at 120/240 V AC

  • Reliable branch-circuit protection with thermal-magnetic trip mechanism
  • High interrupting capacity rated at 14 kA for 120/240 V AC
  • Compact DIN-rail mount fits panels at just 0.71 in wide
  • Secure screw-clamp terminals accept 18 to 8 AWG conductors
  • Certified to UL 1077 for supplementary protector applications

C60SP 2 A Miniature Circuit Breaker

The Schneider Electric M9F22102 is a single-pole supplementary protector rated at 2 A for branch circuit protection. It suits panels that require IEC and UL 1077 recognised devices on DIN rail.

Thermal Magnetic Trip and 14 kA Interrupting

A thermal magnetic mechanism provides overload and short-circuit response on AC circuits up to 240/415 V. The unit delivers a maximum AIR rating of 14 kA at 120/240 V AC and is also rated for 60 V DC operation.

DIN Rail Mount with Screw Clamp Terminals

The toggle actuator and DIN rail mounting style allow quick installation in standard enclosures. Screw clamp terminals accept conductors from 18 AWG to 8 AWG within a 3.19 in by 0.71 in by 2.83 in footprint.

Highlights

  • Reliable branch-circuit protection with thermal-magnetic trip mechanism
  • High interrupting capacity rated at 14 kA for 120/240 V AC
  • Compact DIN-rail mount fits panels at just 0.71 in wide
  • Secure screw-clamp terminals accept 18 to 8 AWG conductors
  • Certified to UL 1077 for supplementary protector applications

Specifications

BrandSCHNEIDER ELECTRIC

Questions about this item

How do I mount the C60SP 1-pole breaker and which wiring step is often missed?

Snap the breaker onto a DIN rail and secure the screw-clamp terminals with wire between 18 AWG and 8 AWG; the step often missed is confirming the conductor fits the clamp range before tightening.

What maintenance or replacement will the 2 A thermal-magnetic breaker need over time?

No routine maintenance is required; replace the unit if it trips repeatedly under normal load, shows discoloration at the terminals, or fails to reset cleanly after a fault.

What is the first limit reached when the 2 A breaker runs continuously at full load?

The thermal element will trip first on sustained overload, while the magnetic release responds only to short-circuit currents up to the 14 kA interrupting rating.