Schneider Electric LUCB32B Overload Module 8-32A 3P Class 10 24VAC
Protects motors from 8 to 32 amps with a Class 10 trip curve and 24 V AC control voltage
- TypeIndustrial Electrical Controls & Automation
- Length4.000
- ColorTransparent
- Weight0.3
- Adjustable motor protection 8–32 A with manual reset
- Trip Class 10 response limits thermal stress on windings
- 24 V AC coil integrates with TeSys Ultra starters
- Certified to IEC 60947-6-2, CE, UL, CSA and ATEX
- Compact 4.000 mm transparent housing weighs .3 kg
Motor-current protection
The Schneider Electric LUCB32B overload module provides adjustable motor-current protection from 8 A to 32 A for three-phase circuits. It operates on a 24 V AC coil and is designed for use with TeSys Ultra starters. Trip Class 10 response and manual reset suit standard industrial motor-starting duties.
Standards and wiring
The module carries ASEFA, ATEX, CCC, CE, CSA, CSA C22.2, EAC, IEC 60947-6-2 and UL listings plus Green Premium RoHS/REACH compliance. Wire-lead terminals simplify panel wiring. A maximum voltage rating of 690 V AC covers common industrial supply levels.
Installation checks
Verify that the motor full-load current falls within the 8 A to 32 A adjustment range. Confirm the control circuit supplies 24 V AC and that the starter is a TeSys Ultra model. Ensure the enclosure can accommodate the 4.000 length dimension and that the 158 °F maximum operating temperature is not exceeded.
Highlights
- Adjustable motor protection 8–32 A with manual reset
- Trip Class 10 response limits thermal stress on windings
- 24 V AC coil integrates with TeSys Ultra starters
- Certified to IEC 60947-6-2, CE, UL, CSA and ATEX
- Compact 4.000 mm transparent housing weighs .3 kg
Specifications
| Brand | Schneider Electric |
|---|---|
| Model | LUCB32B |
| Type | Industrial Electrical Controls & Automation |
| Length | 4.000 |
| Color | Transparent |
| Weight | 0.3 |
Questions about this item
Will the 8-32 A adjustment range need recalibration after extended operation?
The overload module is factory calibrated across the 8-32 A range and does not require periodic recalibration; replacement is only needed if the unit trips repeatedly or shows physical damage.
What limit appears first when the LUCB32B runs continuously at 32 A?
The maximum operating temperature of 158 °F is the first sustained-use limit; exceeding it can cause premature tripping or permanent damage to the trip mechanism.
How much heat does the module generate when powered at 24 V AC all day?
Power dissipation is low because the coil draws only the 24 V AC control voltage; the unit stays well below its 158 °F limit in a ventilated enclosure under normal load.