Schneider Electric
Schneider Electric LR9D5369 Overload Relay 90-150 A 690 V AC Trip Class 10
Three-pole thermal overload relay protects motors from 90 A to 150 A at up to 690 V AC with Trip Class 10 and auto or manual reset
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- Protects motors from overheating with 90-150 A thermal range
- Handles up to 690 V AC for industrial power circuits
- Trip Class 10 ensures fast response to overload conditions
- Auto and manual reset options simplify maintenance recovery
- Direct contactor mounting with screw clamp terminals speeds installation
Overload Relay 90-150 A 690 V AC
The Schneider Electric LR9D5369 is a thermal overload relay designed for industrial motor protection. It suits maintenance engineers and panel builders who need reliable overload monitoring for three-phase circuits up to 690 V AC.
Trip Class 10 Thermal Protection
The relay operates at Trip Class 10 using a thermal sensing element with a current setting range of 90 A to 150 A. It provides automatic and manual reset options for flexible recovery after a trip event in normal operating conditions.
Direct Contactor Mount with Screw Clamp Terminals
The unit mounts directly to compatible TeSys Deca contactors using screw clamp terminals for secure wiring. It includes 1NO/1NC auxiliary contacts for status signalling and control circuit integration without additional accessories.
Highlights
- Protects motors from overheating with 90-150 A thermal range
- Handles up to 690 V AC for industrial power circuits
- Trip Class 10 ensures fast response to overload conditions
- Auto and manual reset options simplify maintenance recovery
- Direct contactor mounting with screw clamp terminals speeds installation
Specifications
| Brand | SCHNEIDER ELECTRIC |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
How do I mount the LR9D5369 directly onto a TeSys Deca contactor and set the dial?
Align the relay with the contactor terminals, secure the direct-mount clips, then rotate the adjustment dial to the required value between 90 A and 150 A.
Which parts of the LR9D5369 typically need replacement after extended service?
The thermal sensing elements and the 1NO/1NC auxiliary contacts are the components most likely to require replacement after prolonged operation.
At what current does the LR9D5369 trip first during a sustained overload?
The relay trips when the current exceeds the dial setting, which can be adjusted from 90 A up to 150 A.