Schneider Electric
Schneider Electric LC1K0610B7 Miniature Magnetic Contactor 24V AC 3-pole 6A 1NO
A 3-pole IEC miniature magnetic contactor with 24V AC coil, 6A inductive rating, 1NO auxiliary contact and DIN-rail mounting
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- Miniature IEC contactor fits tight panels at 1.77 in wide
- 24 V AC coil simplifies low-voltage control circuits
- 6 A inductive rating handles small motor loads reliably
- 1 NO auxiliary contact provides direct status feedback
- DIN-rail or plate mounting enables quick cabinet installation
IEC Miniature Magnetic Contactor
The Schneider Electric LC1K0610B7 is a three-pole IEC contactor with a 24 V AC coil and a single normally-open auxiliary contact. It handles up to 6 A inductive and 15 A resistive loads on DIN-rail or plate mounting.
Thermals noise and power draw
The coil operates at 24 V AC with no enclosure rating, so heat dissipation depends on the cabinet ventilation provided by the installer. Screw-clamp terminals ensure a secure connection that minimises resistive losses during normal operation.
6 A inductive rating decides fit
This contactor suits circuits where the inductive full-load current does not exceed 6 A at the stated coil voltage. Applications requiring higher inductive current, a reversing function or an enclosed body will need a different model.
Highlights
- Miniature IEC contactor fits tight panels at 1.77 in wide
- 24 V AC coil simplifies low-voltage control circuits
- 6 A inductive rating handles small motor loads reliably
- 1 NO auxiliary contact provides direct status feedback
- DIN-rail or plate mounting enables quick cabinet installation
Specifications
| Brand | SCHNEIDER ELECTRIC |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
How do I mount the contactor and which wiring step is most often missed?
Clip the unit onto a DIN rail or screw it to a plate, then tighten the three screw-clamp terminals to the specified torque — skipping the torque check is the common error
What part will need replacement after extended operation?
The main contacts are rated for 6 A inductive and 15 A resistive loads; they wear over time and the whole contactor must be replaced when contact resistance rises
What limit appears first during continuous running?
The 6 A inductive current rating at 24 V AC coil voltage is the limiting factor under sustained use