Schneider Electric
Schneider Electric LADN22 Auxiliary Contact Block 2NO/2NC 10A 690V
Adds two normally-open and two normally-closed contacts rated 10 A at 690 V to TeSys Deca contactors via screw-clamp terminals
- TypeIndustrial Electrical Controls & Automation
- ColorDark Gray
- Adds four auxiliary contacts for expanded control logic
- 10 A rating handles standard industrial loads
- 690 V AC rating suits common supply voltages
- Clip-on front mounting speeds panel assembly
- Mirror-certified NC contacts improve safety-circuit reliability
TeSys Deca Auxiliary Contact Block
The Schneider Electric LADN22 is an instantaneous auxiliary contact block designed for TeSys Deca contactors and control relays. It adds four extra contacts to the control circuit, giving installers additional signalling or interlocking capacity in motor-starter and automation panels.
Sustained-load behaviour
The block carries a continuous thermal current of 10 A at up to 690 V AC, so it handles long-duration coil-holding and status-feedback duties without derating. NC mirror certification ensures the normally-closed contacts reliably reflect the main-pole state even after thousands of operations.
Upgrade context
It replaces a missing or worn front-mount auxiliary block on LC1D, LC1F or CAD devices when extra normally-open and normally-closed circuits are required. The jump is worth it when the existing contactor has no free auxiliary positions left and the application demands certified mirror contacts for safety interlocks.
Highlights
- Adds four auxiliary contacts for expanded control logic
- 10 A rating handles standard industrial loads
- 690 V AC rating suits common supply voltages
- Clip-on front mounting speeds panel assembly
- Mirror-certified NC contacts improve safety-circuit reliability
Specifications
| Brand | SCHNEIDER ELECTRIC |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Color | Dark Gray |
Questions about this item
Does the 10 A auxiliary contact block generate noticeable heat or noise when energised continuously?
It is a passive electromechanical contact block with no fan or active electronics, so it runs silently and produces only minimal heat from contact resistance at rated load.
Which contactor or relay must I already own for the clip-on front mounting to work?
It mounts directly on TeSys Deca contactors LC1D, LC1F and control relays CAD; no separate bracket or adapter is required.
Will the screw-clamp terminals accept the same wire gauges I use on my older TeSys Deca contactors?
Yes, the block uses standard screw-clamp terminals compatible with the wiring practice of existing TeSys Deca contactors and CAD relays.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.