Schneider Electric GV3P40 Manual Motor Starter 40A 600V
Three-phase manual motor starter rated 40 A at 600 V AC with adjustable overload up to 40 A
- TypeIEC
- Colordark grey
- Handles up to 40 A motor loads
- Three-phase power ratings from 10 hp to 30 hp
- Single-phase ratings of 3 hp at 120 V and 5 hp at 240 V
- Rated for 600 V AC maximum operating voltage
- TeSys Deca series with selector-switch operator
Motor Starter for Three-Phase Loads
The Schneider Electric GV3P40 is a manual motor starter rated at 40 A and 600 V AC for three-phase circuits. It belongs to the TeSys Deca series and uses a selector-switch operator for direct on-off control. Suitable for industrial panels that need a compact IEC-type starter without a separate contactor.
Current Setting Is the Deciding Factor
The maximum overload relay current setting is fixed at 40 A, so the starter only protects motors whose full-load current falls at or below this value. At 208 V AC it handles up to 10 hp, at 240 V AC up to 10 hp, at 480 V AC up to 25 hp and at 600 V AC up to 30 hp. Single-phase ratings are 3 hp at 120 V AC and 5 hp at 240 V AC.
No Extra Accessories Included
The unit ships as the starter body only; no auxiliary contacts, enclosures or busbar links are bundled. Installers must source any required mounting hardware, wiring accessories or optional add-on blocks separately. This keeps the package focused on the core protection function for buyers who already have the supporting components.
Highlights
- Handles up to 40 A motor loads
- Three-phase power ratings from 10 hp to 30 hp
- Single-phase ratings of 3 hp at 120 V and 5 hp at 240 V
- Rated for 600 V AC maximum operating voltage
- TeSys Deca series with selector-switch operator
Specifications
| Brand | Schneider Electric |
|---|---|
| Model | GV3P40 |
| Type | IEC |
| Color | dark grey |
Questions about this item
What does the 40 A current rating mean for a motor in a real installation?
The starter protects motors drawing up to 40 A, covering single-phase loads up to 5 hp at 240 V and three-phase loads up to 30 hp at 600 V.
How does the 600 V AC maximum voltage rating limit practical use?
It caps the starter at 600 V AC systems; the same unit handles 480 V three-phase motors up to 25 hp and 240 V three-phase motors up to 10 hp.
What mounting space does the TeSys Deca GV3P40 need inside a panel?
The dark grey IEC unit fits standard DIN-rail cut-outs for three-pole manual starters; allow clearance for the selector-switch operator and wiring terminals.