Schneider Electric GV2ME16 Manual Motor Starter 3P 14A 690V video accessory
A three-pole manual motor starter rated 14 A with push-button operation for three-phase circuits up to 690 V AC
- TypeIndustrial Electrical Controls & Automation
- Colordark grey
- Protects motors up to 14 A overload current
- Handles three-phase power up to 690 V AC
- Controls up to 10 hp at 480 V and 600 V
- Push-button operator for direct manual control
- TeSys Deca series built for industrial durability
Product Identity
The Schneider Electric GV2ME16 is a three-pole manual motor starter rated for 14 A and 690 V AC. It belongs to the TeSys Deca series and provides push-button operation for industrial motor control.
Compatibility Check
Verify that your motor’s full-load current does not exceed 14 A and that the supply voltage is within the 690 V AC maximum. Confirm the application uses three-phase power and that the horsepower ratings at 208 V, 240 V, 480 V and 600 V match your motor nameplate.
Sustained Operation
The device is designed for continuous duty at its 14 A current setting with a maximum overload relay setting of 14 A. It handles rated three-phase loads at 208 V, 240 V, 480 V and 600 V without derating. The push-button operator remains functional during prolonged use.
Highlights
- Protects motors up to 14 A overload current
- Handles three-phase power up to 690 V AC
- Controls up to 10 hp at 480 V and 600 V
- Push-button operator for direct manual control
- TeSys Deca series built for industrial durability
Specifications
| Brand | SCHNEIDER ELECTRIC |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Color | dark grey |
Questions about this item
Does the Schneider Electric GV2ME16 ship with any cables or mounting hardware, or must they be purchased separately?
The starter is supplied as the unit only; power cables, control wiring and mounting accessories are not included and must be sourced separately.
The GV2ME16 is rated 14 A and 690 V — how do I decide whether this model suits my motor?
Match the motor full-load current to the 14 A maximum overload setting and confirm the supply voltage does not exceed 690 V AC; the starter covers three-phase ratings up to 10 hp at 480 V and 600 V.
What does the 14 A current rating mean when the starter is installed in a live panel?
It is the maximum continuous current the starter can carry and the upper limit of the adjustable overload relay, so the protected motor must draw 14 A or less under normal operation.