Schneider Electric
Schneider Electric electrical box
Manual motor starter with thermal overload protection from 0.16 to 0.25 A at 600 V AC
- TypeEnclosures
- Three-pole protection for motor circuits up to 600 V AC
- Adjustable thermal overload from 0.16 A to 0.25 A
- Selector-switch operator for clear manual control
- Screw-clamp terminals give secure wiring connections
- IP20-rated enclosure with fire-resistant material
Schneider Electric GV2P02 starter
This Schneider Electric GV2P02 manual motor starter provides thermal overload protection for three-phase circuits up to 600V AC. It suits IEC-style panels where a compact selector-switch operator is preferred. The TeSys Deca series unit covers a 0.16 to 0.25 A setting range.
Before ordering
Verify that your control circuit operates at 50 or 60 Hz and that the load current falls within the 0.16 to 0.25 A adjustment window. Ensure the enclosure can accept an IP20-rated device with screw-clamp terminals. Confirm three-phase supply and 600V AC maximum voltage compatibility.
Under sustained load
Thermal overload protection reacts to prolonged overcurrent rather than momentary spikes. The fire-resistant housing maintains integrity during continuous operation at the 0.25 A maximum setting. Screw-clamp terminals resist loosening from vibration over extended duty cycles.
Highlights
- Three-pole protection for motor circuits up to 600 V AC
- Adjustable thermal overload from 0.16 A to 0.25 A
- Selector-switch operator for clear manual control
- Screw-clamp terminals give secure wiring connections
- IP20-rated enclosure with fire-resistant material
Specifications
| Brand | SCHNEIDER ELECTRIC |
|---|---|
| Type | Enclosures |
Questions about this item
Does the Schneider Electric GV2P02 starter ship with an enclosure or must one be purchased separately?
The unit is supplied with no enclosure; the NEMA rating is listed as no enclosure and the IP rating is IP20.
How do I choose the correct overload setting for my motor using the 0.16 to 0.25 A range?
Set the thermal overload dial between the minimum of 0.16 A and the maximum of 0.25 A to match the motor full-load current.
What does the 600 V AC rating mean when the starter is installed in a control panel?
It indicates the maximum voltage the three-pole starter can safely switch at 50 or 60 Hz in an industrial circuit.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Thomas & Betts TY523M Cable Tie 18lb 4in Natural Nylon Stainless Steel Locking Clip Pack 100
CALBRITE S60700FDCC Weatherproof Electrical Box 5.90" x 2.83" 25 cu in
- Electrical Boxes &…
HOFFMAN A12P10G Interior Panel Steel 10.75in H 8.88in W 14 Gauge
- Electrical Boxes &…