Schneider Electric
Schneider Electric CA2KN40G7 IEC Control Relay 4NO 120V AC 10A
IEC control relay with four normally-open contacts rated 10 A at 120 V AC coil voltage for DIN-rail or surface mounting
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- Controls four circuits with a single 120 V AC coil
- Handles up to 10 A on AC loads at 600 V
- Mounts on DIN rail or flat surface for flexible installation
- Silver-nickel contacts deliver reliable switching at 2 A DC rating
- Compact 1.77 × 2.24 × 2.28 in body fits tight panels
IEC Control Relay 4NO 120V AC
The Schneider Electric CA2KN40G7 is an IEC control relay with four normally open contacts rated at 10 A for AC loads up to 600 V. It operates from a 120 V AC coil consuming 4.5 VA and mounts on DIN rail or surface. The silver-nickel contacts are housed in a transparent body rated IP2X.
Upgrade from lower-contact-count relays
This relay replaces units that offer fewer than four normally open poles or lower AC contact ratings at 120 V, 240 V, 480 V and 600 V. The jump is worth it when a single device must switch multiple circuits at 10 A without adding extra relays to the panel.
Suits panels needing four NO poles at 10 A
It suits control panels that require four normally open contacts at 10 A with screw-clamp wiring and DIN-rail mounting. Buyers who need changeover contacts, DC coil operation or a higher IP rating should look at something else.
Highlights
- Controls four circuits with a single 120 V AC coil
- Handles up to 10 A on AC loads at 600 V
- Mounts on DIN rail or flat surface for flexible installation
- Silver-nickel contacts deliver reliable switching at 2 A DC rating
- Compact 1.77 × 2.24 × 2.28 in body fits tight panels
Specifications
| Brand | SCHNEIDER ELECTRIC |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
What mounting options does the 1.77 in wide relay body support?
The relay body mounts on DIN rail and can also be surface mounted using the integral screw-clamp terminals.
What wiring step is often missed when connecting the 120V AC coil to the screw-clamp terminals?
The coil terminals must be wired to the 120V AC supply at 50/60 Hz; forgetting to match the 4.5 VA coil rating can cause overheating.
When should the silver-nickel contacts be inspected given the 10 A AC rating at 120/240/480/600V?
Inspect contacts after high-cycle operation or if the 122 °F maximum operating temperature is regularly approached, as contact wear increases under sustained load.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.