Schneider Electric
Schneider Electric 9001SKR1RH6 Red 30mm Push Button
A 30 mm red momentary push button rated 10 A at 600 V AC with IP66 and NEMA 1, 2, 3, 3R, 4, 4X, 6, 12, 13 protection
- TypeLight Switch
- Size/Dimensions30mm
- Color/FinishRed
- Color MappingRed
- Momentary flush action gives precise single-press control
- 30 mm red plastic head fits standard panel cut-outs
- 10 A at 600 V AC rating handles demanding circuits
- IP66 and NEMA 4X sealing resists dust and water ingress
- Certified to UL 508, CSA 22.2 and IEC 60947 standards
Schneider Electric 30 mm Red Push Button
The Schneider Electric 9001SKR1RH6 is a flush-mount, momentary push button operator with a 30 mm red plastic head. It provides a single normally closed contact rated at 10 A at 600 V AC for industrial control circuits.
Suited for panels needing a corrosion-resistant
This operator fits panels requiring NEMA 1, 2, 3, 3R, 4, 4X, 6, 12, 13 and IP66 sealing with a corrosion-resistant thermoplastic bezel. It is not suitable for applications requiring an illuminated head, a maintained action, or a normally open contact configuration.
Contact form 1NC defines the switching logic
The single normally closed contact opens the circuit only when the button is pressed, making this the correct part for stop or emergency-off functions wired for fail-safe operation.
Highlights
- Momentary flush action gives precise single-press control
- 30 mm red plastic head fits standard panel cut-outs
- 10 A at 600 V AC rating handles demanding circuits
- IP66 and NEMA 4X sealing resists dust and water ingress
- Certified to UL 508, CSA 22.2 and IEC 60947 standards
Specifications
| Type | Light Switch |
|---|---|
| Brand | SCHNEIDER ELECTRIC |
| Size/Dimensions | 30mm |
| Color/Finish | Red |
| Color Mapping | Red |
Questions about this item
How much continuous current can the 10A @ 600V AC contacts carry before heat becomes the limiting factor?
The contacts are rated for 10A at 600V AC under NEMA A600/Q600, so sustained loads up to that current are within the published thermal limit.
What noise, heat or power draw should be expected when the button is actuated continuously in a panel?
As a passive momentary operator it generates no audible noise, negligible heat and draws no power of its own; only the switched load determines panel thermals.
Which contact blocks or mounting accessories must already be on hand to complete the installation?
The operator uses standard 30 mm mounting and requires a compatible contact block (1NC form shown) and any legend plate the application needs.