Schneider Electric
Schneider Electric 9001KR1BH6 30 mm push button operator, 1NC, black
A 30 mm flush push-button operator with a black metal head, 1NC contact rated 10A at 600V AC, and IP66/NEMA 4, 6, 12, 13 protection
- Color MappingBlack
- TypeIndustrial Electrical Controls & Automation
- Momentary flush action for precise control
- 30 mm metal head fits standard panels
- 1NC contact rated 10 A at 600 V AC
- NEMA 1, 2, 3, 3R, 4, 12, 13 and IP66 sealing
- Certified to CE, CSA, UL, RoHS and REACH standards
Industrial flush push button, 30 mm
The Schneider Electric 9001KR1BH6 is a momentary flush push button operator built for industrial control panels. It carries a single normally-closed contact rated at 10 A and 600 V AC, designated A600/Q600, and suits machinery start-stop or emergency-stop circuits that require a compact metal operator.
Sealed to NEMA 1, 2, 3, 3R, 4, 6, 12, 13 and IP66
The chrome-plated die-cast aluminium bezel and metal head resist dust, water jets and temporary submersion, so the switch stays reliable in wash-down areas and outdoor enclosures. No fan or active cooling is involved, therefore the device adds no acoustic noise and draws no power beyond the control circuit it switches.
Screw-clamp terminals and 30 mm panel cut-out
Wiring uses screw-clamp connections that accept standard ferrules or stripped conductors for secure termination in vibration-prone cabinets. The single 30 mm mounting hole simplifies panel layout, while CE, CSA, UL, REACH, RoHS and WEEE markings confirm compliance for global installations.
Highlights
- Momentary flush action for precise control
- 30 mm metal head fits standard panels
- 1NC contact rated 10 A at 600 V AC
- NEMA 1, 2, 3, 3R, 4, 12, 13 and IP66 sealing
- Certified to CE, CSA, UL, RoHS and REACH standards
Specifications
| Brand | SCHNEIDER ELECTRIC |
|---|---|
| Color Mapping | Black |
| Type | Industrial Electrical Controls & Automation |
Questions about this item
How do I mount the 30 mm push button operator and what step is often missed?
Drill a 30 mm panel cutout, insert the operator through the front, and secure it from behind with the locking nut; the step often missed is tightening the nut to the specified torque so the IP66 seal compresses evenly.
Which part will need replacement first under normal industrial use?
The internal 1NC contact block is rated for standard mechanical life; when the screw-clamp terminals show contact wear or the momentary action becomes inconsistent, replace the contact block rather than the whole operator.
What thermal or electrical limit appears first during sustained operation at full load?
The contact rating of 10 A at 600 V AC defines the limit; continuous current above 10 A or excessive switching frequency will cause contact heating before the NEMA 1, 12, 13, 2, 3, 3R, 4, 6 or IP66 enclosure ratings are challenged.