Robertshaw
Robertshaw 780-715 Ignition Module thermostat
A universal spark-ignition module for NG/LP gas valves 7000 BDER, 7100 DER and 7200IPER
- TypeLearning Thermostats
- Spark ignition without lockout for reliable start-up
- Compatible with 7000, 7100 and 7200 gas valves
- Works with natural gas and LP supplies
- Universal ignition control simplifies replacement
- New Robertshaw module ready for HVAC systems
Robertshaw 780-715 Ignition Module
The Robertshaw 780-715 is a universal spark-ignition control designed for gas-fired heating equipment. It operates with natural gas or LP systems and carries a nonlockout design that keeps the ignition sequence active. Contractors and maintenance technicians use it as a direct replacement for worn or failed ignition modules in residential and light-commercial appliances.
Replaces older lockout-style modules
This module upgrades systems that previously used lockout-type ignition controls which shut down completely after a failed trial for ignition. The nonlockout behaviour allows continuous retry cycles, reducing nuisance service calls on intermittent flame-proving issues. The jump is worthwhile when the existing control causes repeated hard lockouts that require manual reset, especially on 7000 BDER, 7100 DER or 7200IPER gas valves.
Limited to spark-ignition, nonlockout applications
The control only supports spark-ignition systems and cannot operate hot-surface or direct-ignition configurations. It is restricted to use with the specified gas-valve series and will not function with valves outside the 7000, 7100 or 7200 families. Installers must verify valve compatibility before fitting, as the module provides no diagnostic codes or communication interface for broader system integration.
Highlights
- Spark ignition without lockout for reliable start-up
- Compatible with 7000, 7100 and 7200 gas valves
- Works with natural gas and LP supplies
- Universal ignition control simplifies replacement
- New Robertshaw module ready for HVAC systems
Specifications
| Brand | ROBERTSHAW |
|---|---|
| Type | Learning Thermostats |
Questions about this item
Which gas valves does the Robertshaw 780-715 module connect to?
It is designed for use with 7000 BDER, 7100 DER and 7200IPER gas valves.
What wiring step is most often missed when fitting the 780-715?
Installers frequently forget to connect the flame-sense lead to the burner, so the module cannot prove ignition.
When should the 780-715 ignition module be replaced?
Replace it if the spark sequence fails, the valve does not open after trial-for-ignition, or the unit locks out repeatedly.