Adjustable SPDT air pressure switch for HVAC and furnace control with conduit housing, screw terminals and 0.02 in wc differential
- TypeCable Ties
- Adjustable SPDT switch suits HVAC and furnace control
- 1 A pilot duty at 120 VA with 5 A at 120-277 V AC
- Stainless steel conduit box housing protects internal components
- Includes adjustment tool and mounting hardware for installation
- Maximum differential pressure setting of 0.02 in wc
Pressure switch for HVAC systems
The Robertshaw 2374-506 is a conduit-box air pressure switch designed for commercial and residential HVAC equipment. It handles air filtration, furnace control and humidity detection tasks with a stainless-steel housing rated for 1 A pilot duty at 120 VA and 5 A at 120 to 277V AC or 28V DC.
SPDT screw-terminal wiring for panel mounting
The switch uses a single-pole double-throw contact form with screw terminals, allowing direct integration into control panels without additional connectors. Its conduit-box housing protects the terminals while the adjustable differential pressure setting of 0.02 in wc lets technicians calibrate the actuation point on site.
Adjustment tool and mounting hardware included
An adjustment tool ships in the box so the differential pressure can be set without sourcing a separate instrument. Mounting hardware is also supplied, letting installers secure the unit to the panel immediately instead of ordering brackets or fasteners separately.
Highlights
- Adjustable SPDT switch suits HVAC and furnace control
- 1 A pilot duty at 120 VA with 5 A at 120-277 V AC
- Stainless steel conduit box housing protects internal components
- Includes adjustment tool and mounting hardware for installation
- Maximum differential pressure setting of 0.02 in wc
Specifications
| Brand | ROBERTSHAW |
|---|---|
| Type | Cable Ties |
Questions about this item
What is the maximum differential pressure setting before the switch activates under sustained use?
The maximum differential pressure setting is 0.02 in wc before the switch activates.
How much heat or noise does the switch produce when running all day in an HVAC system?
The switch has no moving parts that generate heat or noise during continuous operation.
What voltage supply must I already have for the screw terminals to work?
You need a 120V AC, 277V AC, or 28V DC supply to match the rated input voltages.