Rfwel Infra
Rfwel Infra 600-Series Low Loss Coaxial RF Cable 200 ft N-Male to N-Male
200 ft 600-series low-loss coaxial cable with N-Male connectors, rated to 9.3 GHz and 40 kW peak power, attenuation under 1.72 dB per 100 ft at 450 MHz and under 6.56 dB per 100 ft at 4.9 GHz
- TypeCoax Cables
- ColorBlack
- Length200 ft.
- Connector Number2
- Connector DetailN-Male to N-Male
- Terminal GenderMale to Male
- Low-loss 600-series cable rated to 9.3 GHz max frequency
- Handles up to 40 kW peak power for demanding RF applications
- Attenuation under 1.72 dB per 100 ft at 450 MHz
- Attenuation under 6.56 dB per 100 ft at 4.9 GHz
- Lightweight construction at 0.13 lb per foot for easier installation
Signal Integrity
This 200 ft 600-series low loss coaxial cable carries RF signals up to 9.3 GHz with a 40 kW peak power rating. The solid copper clad aluminium inner conductor and tape plus tinned copper braid outer conductor keep attenuation low for long runs in repeater and distribution systems.
Installation Fit
Installers who need a single 200 ft N-Male to N-Male assembly for point-to-point links will find the ready-made length convenient. Projects requiring shorter segments, different connector types or pre-terminated jumper sets should source a different configuration.
Attenuation Profile
At 450 MHz the cable shows less than 1.72 dB loss per 100 ft, rising to 6.56 dB per 100 ft at 4.9 GHz, which determines whether the link budget closes over the full 200 ft span.
Highlights
- Low-loss 600-series cable rated to 9.3 GHz max frequency
- Handles up to 40 kW peak power for demanding RF applications
- Attenuation under 1.72 dB per 100 ft at 450 MHz
- Attenuation under 6.56 dB per 100 ft at 4.9 GHz
- Lightweight construction at 0.13 lb per foot for easier installation
Specifications
| Brand | Rfwel Infra |
|---|---|
| Model | RFWCAB600NMNM200 |
| Type | Coax Cables |
| Color | Black |
| Length | 200 ft. |
| Connector Number | 2 |
| Connector Detail | N-Male to N-Male |
| Terminal Gender | Male to Male |
Questions about this item
What connectors are on the 200 ft cable and do I need to buy any adapters separately?
The cable has N-Male connectors on both ends. No adapters are included in the box.
Is the 600-series 200 ft length the right choice for a 4.9 GHz link?
The 600-series is rated to 9.3 GHz and shows 6.56 dB loss per 100 ft at 4.9 GHz.
What does the 9.3 GHz maximum frequency mean for my installation?
It is the highest frequency the cable is specified for. At 4.9 GHz attenuation is 6.56 dB per 100 ft.