Red Hat
Red Hat JB8214073CSA Solenoid Valve 2-Way 110/120V AC Cv 35
A 2-way normally-open solenoid valve with a Cv of 35 for 110/120V AC systems
- TypeDrain Components
- High flow capacity with Cv 35 rating
- Normally open design allows default flow state
- Dual 110/120V AC voltage compatibility
- Aluminum body construction for corrosion resistance
- NBR seals suit air and inert gas applications
High-Flow Gas Shut-Off Valve
The Red Hat JB8214073CSA is a two-way, normally open solenoid valve built for high-flow gas shut-off applications. Its aluminium body and 1 1/2 inch nominal pipe size suit industrial piping systems that require reliable on-off control of air or inert gas. The 1 5/8 inch orifice and Cv 35 rating indicate substantial flow capacity for the intended media.
Thermals Noise and Power Draw
The valve operates on 110V AC or 120V AC supply with a coil enclosure that includes a junction box for protected wiring. NBR seals are compatible with the specified media and operating pressure differential of 5 psi maximum for air or inert gas. Power consumption is limited to the coil energising current during the open state.
Sustained Load Behaviour
Under continuous energised operation the coil maintains the valve in its open position within the 5 psi differential limit for air or inert gas. The normally open configuration means flow is interrupted only when power is applied, so sustained load equates to continuous coil energisation. Fuel gas and fuel oil service are not applicable for this model.
Highlights
- High flow capacity with Cv 35 rating
- Normally open design allows default flow state
- Dual 110/120V AC voltage compatibility
- Aluminum body construction for corrosion resistance
- NBR seals suit air and inert gas applications
Specifications
| Type | Drain Components |
|---|---|
| Brand | Red Hat |
| Model | JB8214073CSA |
Questions about this item
How do I install the 1-1/2 inch NPT solenoid valve and what wiring step is often missed?
Thread the aluminum body onto 1-1/2 inch NPT piping using pipe sealant, then connect 110/120V AC supply wires inside the integral junction box; the step often missed is grounding the enclosure through the box lug.
Which seal material will need replacement first and how often should it be inspected?
The NBR (nitrile) seals on the 1 5/8 inch orifice should be inspected annually and replaced if swelling, cracking, or leakage appears, as they are the primary wear component in air or inert gas service.
What pressure limit will be reached first during continuous operation at 120V AC?
The 5 psi maximum operating pressure differential for air or inert gas is the limiting factor; exceeding it prevents the normally open valve from closing reliably.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Taylor 70204 Acrylic Coated Polyester Gray Hot Shot BoatGuard Boat Cover
- Transparent
BoatBuckle F12071 Kwik-Lok Gunwale Tie-Down Stainless Steel
- Transparent