Red Hat
Red Hat JB8214063CSA Solenoid Valve 2-Way Normally Open 110V 120V AC Cv 32
A 2-way normally open solenoid valve for high-flow gas shut-off with a Cv of 32 operating at 110V or 120V AC
- TypeDrain Components
- High flow capacity with Cv 32 rating
- Normally open design allows flow when de-energized
- Dual voltage compatibility at 110V and 120V AC
- Aluminum body construction for lightweight durability
- NBR seals suitable for air and inert gas applications
Solenoid Valve for High-Flow Gas Shut-Off
The Red Hat JB8214063CSA is a 2-way, normally open solenoid valve designed for high-flow gas shut-off applications. It suits industrial and commercial systems requiring reliable on-off control of air, inert gas, or fuel gas. The aluminum body and NBR seals provide compatibility with these media. This valve is not for liquid fuel oil service, as the maximum operating pressure differential for fuel oil is not applicable.
Pressure Limit Defines Safe Operating Range
The valve operates at a maximum pressure differential of 5 psi for both air/inert gas and fuel gas. This low-pressure rating restricts use to systems that remain within this limit. Exceeding 5 psi can prevent proper opening or cause leakage. Builders needing higher pressure ratings must select a different valve class.
Cv 32 Determines Flow Capacity
The coefficient of volume (Cv) is 32, which quantifies the flow rate through the 1-5/8 inch orifice at a given pressure drop. This single figure decides whether the valve can deliver the required gas volume for the application. If the system demands a higher flow coefficient, this model will be insufficient.
Highlights
- High flow capacity with Cv 32 rating
- Normally open design allows flow when de-energized
- Dual voltage compatibility at 110V and 120V AC
- Aluminum body construction for lightweight durability
- NBR seals suitable for air and inert gas applications
Specifications
| Type | Drain Components |
|---|---|
| Brand | Red Hat |
| Model | JB8214063CSA |
Questions about this item
Should I choose the 110 V or 120 V AC version for my supply?
The valve is rated for both 110 V and 120 V AC, so either nominal voltage will operate the coil correctly.
What flow can I expect with a Cv of 32 in my system?
A Cv of 32 means the valve passes 32 US gallons per minute of water with a 1 psi pressure drop; actual flow depends on your media and differential pressure.
How does the 5 psi maximum pressure differential limit installation?
The valve is rated for a maximum 5 psi differential for air, inert gas or fuel gas, so the upstream pressure must not exceed downstream pressure by more than 5 psi.